![JPS JMD-STD-90A Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/jps/jmd-std-90a/jmd-std-90a_user-manual_2028052042.webp)
www.jps.com.tw
41
9.3 BP2P Mode:Basic Point To Point Parameter List
BP2P (Basic Point to Point) Group < Refer to chapter -14.4>
No.
Name
Default
Min.
Max.
Unit
Type
*W
218 P2P In-Position_Rage
0
0
30000
pulses
R/W
1
269 Search Home Mode
0
0
8
R/W;R
1
270 Home Offset
0.000
-1000.000
1000.000
mm
R/W
2
273 P2P High Gain Lock Time
500
0
1000
ms
R/W
1
274 Position Set0 (POSx SW=0000)
0.000
-1000000.000 1000000.000
mm
R/W
2
276 Position Set1 (POSx SW=0001)
0.000
-1000000.000 1000000.000
mm
R/W
2
278 Position Set2 (POSx SW=0010)
0.000
-1000000.000 1000000.000
mm
R/W
2
280 Position Set3 (POSx SW=0011)
0.000
-1000000.000 1000000.000
mm
R/W
2
282 Position Set4 (POSx SW=0100)
0.000
-1000000.000 1000000.000
mm
R/W
2
284 Position Set5 (POSx SW=0101)
0.000
-1000000.000 1000000.000
mm
R/W
2
286 Position Set6 (POSx SW=0110)
0.000
-1000000.000 1000000.000
mm
R/W
2
288 Position Set7 (POSx SW=0111)
0.000
-1000000.000 1000000.000
mm
R/W
2
290 Position Set8 (POSx SW=1000)
0.000
-1000000.000 1000000.000
mm
R/W
2
292 Position Set9 (POSx SW=1001)
0.000
-1000000.000 1000000.000
mm
R/W
2
294 Position Set10 (POSx SW=1010)
0.000
-1000000.000 1000000.000
mm
R/W
2
296 Position Set11 (POSx SW=1011)
0.000
-1000000.000 1000000.000
mm
R/W
2
298 Position Set12 (POSx SW=1100)
0.000
-1000000.000 1000000.000
mm
R/W
2
300 Position Set13 (POSx SW=1101)
0.000
-1000000.000 1000000.000
mm
R/W
2
302 Position Set14 (POSx SW=1110)
0.000
-1000000.000 1000000.000
mm
R/W
2
304 Position Set15 (POSx SW=1111)
0.000
-1000000.000 1000000.000
mm
R/W
2
306 P2P Mark Reference Position
0.000
0.000
1000000.000
mm
R/W
2
310
MOTOR side PPM
(Input Pulses Per Meter)
50000
0
100000000 Pls/Meter FR/W;R 2