![JPS JMD-STD-90A Скачать руководство пользователя страница 139](http://html1.mh-extra.com/html/jps/jmd-std-90a/jmd-std-90a_user-manual_2028052139.webp)
www.jps.com.tw
138
※ 14.4.6.2 BP2P Mode:Basic Point To Point:Mode Curve Description
14.4.6.2.1 Mode-Curve:=0 P2P Relative-Incremental Mode
Pr.361
(rpm)
RPM
DIx(18)P2P Trigger
Pr.362
Pr.362
Description:
(The demo use Profile-B Ramp Setting
Pr.274
DOx(60)P2P Ready
Last End
No1.P2P Trigger
Last End
No2.P2P Trigger
Last End
No3.P2P Trigger
Mode Curve=0:P2P Relative-Incremental Mode
BP2P Mode when DIx(18) trigger,DOx(60) change status immediately ,Motor will
Follow Ramp setting,run to Pr.274 setting position,DOx(60) recover original status。
In Relative Mode,when Motor finished setting position,will be:
(Next Start position)=(Last End position)
14.4.6.2.2 Mode Curve:=1 P2P Absolute Mode
RPM
DIx(18)P2P Trigger
Pr.274
DOx(60)P2P Ready
No1.P2P Trigger
No2.P2P Trigger
Absolute Home
No3.P2P Trigger
=1*(Pr.274)
=2*(Pr.274)
=3*(Pr.274)
Pr.361
(rpm)
Pr.362
Pr.362
Mode Curve:=1 P2P Absolute Mode
BP2P Mode when DIx(18) trigger,DOx(60) change status immediately ,Motor will
Follow Ramp setting,run to Pr.274 setting position,DOx(60) recover original status。
In Absolute Mode,when finished search home,will set the Home point as zero。
Description:
(The demo use Profile-B Ramp Setting