※ 14.4.5.3 BP2P Mode:Basic Point To Point:Example
P2P Trigger (Incremental )
Pr.310= by Actual needs
set MOTOR side PPM(Input Pulses Per Meter)。
Pr.388=0
set P2P Position Mode-0= P2P Relative Incremental Mode
Pr.372=1
set P2P Run Profile-0= P2P Profile Type-B
Pr.361=1000
set P2P Profile-B : Top Speed Set
Pr.362=200.0
set P2P Profile-B : Acc/Dec Ramp Time
Pr.363=100.0
set P2P Profile-B : S-Curve Jerk Time
Pr.274=100.000
set Position Set0 (POSx SW=0000)=100.000 mm
Pr.061=18
set DI1= P2P TRIGGER , (select by POSx_SW0~3)
Pr.068=102
set DI8= SERVO-ON
After setting, perform the reset reset
。
Enable DI8
Drive into the excitation state
。
Trigger DI1
Driver trigger P2P-Length/Position=100.000 mm。
※ 14.4.5.4 BP2P Mode:Basic Point To Point:Example
P2P Trigger (Absolutely )
Pr.310= by Actual needs
set MOTOR side PPM(Input Pulses Per Meter)。
Pr.388=1
set P2P Position Mode-0= P2P Absolute Position Mode
Pr.372=1
set P2P Run Profile-0= P2P Profile Type-B
Pr.361=1000
set P2P Profile-B : Top Speed Set
Pr.362=200.0
set P2P Profile-B : Acc/Dec Ramp Time
Pr.363=100.0
set P2P Profile-B : S-Curve Jerk Time
Pr.274=100.000
set Position Set0 (POSx SW=0000)=100.000 mm
Pr.404=500.000
set P2P FORWARD Travel Limit =500.000 mm
Pr.061=18
set DI1= P2P TRIGGER , (select by POSx_SW0~3)
Pr.068=102
set DI8= SERVO-ON
After setting, perform the reset reset
。
Enable DI8
Drive into the excitation state
。
Trigger DI1
Driver trigger P2P-Length/Position =100.000 mm。
After trigger 5 times,and trigger again;Length/Position will limit by Pr.404。