www.jps.com.tw
141
14.4.6.3.2 BP2P Mark Adjustment-2
Pr.428:(M) P2P MARK Position(mm)
Pr.306:P2P Mark Reference Position
Pr.430:P2P MARK-Window
Pr.431:P2P ARC Ratio
Pr.432:P2P ARC Limit
DOx(081):
BP2P Mark Adjustment2
Pr.306
+Pr.430
-Pr.430
+Pr.430
-Pr.430
Pr.428
Pr.428
DIx(034):
DOx(080):
Pr.306
P2P MARK Sensor Input
P2P-MARK Window
P2P-MARK Loss
※ Definitions & Rules:
Pr.430:P2P Mark Window=(Pr.306:P2P Mark Reference Position)
left and right open±Pr.430mm。
Use this kind of Mark adjustment,please set Pr.430 to maximum length。
【Note】when Pr.430=1*setting length,P2P Window will be 100%。
DOx(081),P2P-MARK Loss is inactive at this kind of Mark adjustment。
※ Action Description:
When DIx(018) trigger,current position=0 mm。
when【Disable】DIx(019):
When DIx(034) appeared,Travel-length position will be record = Pr.428
When【Enable】DIx(019):
When DIx(034) appeared,Travel-length position will be record = Pr.428
If Pr.428 value inside DOx(080) range;then DOx(081)=OFF。
If Pr.428 value outside DOx(080) range;then DOx(081)=ON。
Mark Adjustment Rule:
If (Pr.428-Pr.306)* Pr.431(%) < Pr.432;Next Adjust-Value= (Pr.428-Pr.306)*Pr.431(%)
DIx(034),P2P MARK Sensor Input ( DIx )
DIx(019),P2P ARC Enable
DOx(080),P2P:MARK Window
DOx(081),P2P:MARK Loss
DIx(018):
P2P Trigger
First Trigger
Second Trigger
Extend Trigger
Inside Window
Outside Window