background image

 

 
 

Installation Instructions   

 

Issue Date  January 19, 2005 

 

©  2005 Johnson Controls, Inc.

 

1

 

 

T600MSP-2 Programmable Thermostat 

 

Application 

The T600MSP-2 is a multi-stage programmable 
thermostat that provides exceptional accuracy through 
the use of a unique Proportional-Integral (PI) time 
proportioning algorithm. The algorithm virtually 
eliminates temperature offset associated with 
traditional, differential-based on/off thermostats. The 
T600MSP-2 thermostat also uses an adaptive control 
logic algorithm to control the space temperature during 
recovery to minimize overshoot while providing 
maximum comfort. Additionally, the menu driven 
backlit display, plain text menus, and five keys on the 
T600MSP-2 thermostat make operating the thermostat 
easy and intuitive. 

Installation 

Location Considerations 

Locate the T600MSP-2 thermostat: 

• 

on a partitioning interior wall, and approximately 
5 ft. (1.5 m) above the floor in a location of 
average temperature 

• 

away from direct sunlight, radiant heat, outside 
walls, behind doors, air discharge grills, stairwells, 
or outside doors 

• 

away from steam or water pipes, warm air stacks, 
unheated/uncooled areas, or sources of electrical 
interference 

To install the thermostat: 

1.  Remove the security screw on the bottom of the 

thermostat cover using a Phillips-head 
screwdriver. Open the thermostat by pulling on the 
bottom side of the thermostat cover (Figure 1). 

2.  Unlock the Printed Circuit Board (PCB) by 

carefully pressing the locking tab to the right 
(Figure 2). Open the thermostat’s PCB to the left. 

3.  Pull out approximately 6 in. (152 mm) of wires 

from the wall and insert the cable through the hole 
in the base. 

4.  Align the base on the wall, and using the base as 

a template, mark the location of the two mounting 
holes on the wall. Confirm the thermostat base is 
installed with the proper side up. 

5.  Use the supplied anchors and screws for mounting 

on drywall or plaster. Drill two 3/16 in. (4.7 mm) 
holes at the marked locations and tap nylon 
anchors flush to wall surface (Figure 3). 

6.  Position base on the wall, insert screws through 

mounting base, and fasten into wall anchors. Do 
not overtighten screws. 

7.  Swing the thermostat PCB back to the right to 

close. Gently press on the PCB to secure each of 
the locking tabs. 

8.  Pull out the screw terminal blocks using the 

pull-tabs on each connector (Figure 4). 

Note: 

The number of terminals on the terminal 

blocks varies depending on the T600 model. 

IMPORTANT: 

Use this T600MSP-2 

programmable thermostat only as an operating 
control. Where failure or malfunction of the 
thermostat could lead to personal injury or property 
damage to the controlled equipment or other 
property, additional precautions must be designed 
into the system. Incorporate and maintain other 
devices such as supervisory or alarm systems or 
safety or limit controls intended to warn of, or protect 
against, failure or malfunction of the thermostat. 

  Part No. 24-9889-142, Rev. A 

www.johnsoncontrols.com 

Содержание T600MSP-2

Страница 1: ...t cover Figure 1 2 Unlock the Printed Circuit Board PCB by carefully pressing the locking tab to the right Figure 2 Open the thermostat s PCB to the left 3 Pull out approximately 6 in 152 mm of wires...

Страница 2: ...s and reinsert on to the new thermostat To wire the thermostat 1 Strip each wire 1 4 in 6 35 mm and connect to the appropriate terminal according to the wiring diagram Figure 5 2 Gently push excess wi...

Страница 3: ...the selected fan mode 24 VAC from equipment transformer 24 VAC common from equipment transformer 24 VAC for heating stages Energizes on a call for first stage heating Energizes on a call for second s...

Страница 4: ...and to advance to the next menu item MENU key to access the Main User Menu or exit the menu UP DOWN arrow keys to adjust values activate a Temporary Setpoint Configuration Key T600_TEC_Config_Key Fig...

Страница 5: ...ver and press the CONFIG key from the Status Display Menu to enter the Installer Configuration Menu Configures Digital Input 1 Default No Function None See the Configuring the Digital Inputs DI1 and D...

Страница 6: ...hen the message displays the backlight momentarily lights up TOccTime set Y N Each digital input can be programmed in one of five conditions None No function is associated with the input Service A Ser...

Страница 7: ...e the Enabling Frost Protection Frost pr section for setup instructions Enabling Frost Protection Frost pr Frost protection establishes a minimum heating setpoint of 42 F 5 5 C to prevent freezing in...

Страница 8: ...rature control but could accelerate the wear of mechanical components in the equipment To set the maximum number of heating cycles per hour while in the Installer Configuration Menu 1 Answer NO to all...

Страница 9: ...emporary setpoint is entered The range is adjustable from 0 to 12 hours To change the temporary occupancy time while in the Installer Configuration Menu 1 Answer NO to all prompts until the temporary...

Страница 10: ...lue The display now shows the cooling lockout prompt See the Setting the Cooling Lockout C lock section for instructions Setting the Cooling Lockout C lock This feature disables cooling operation base...

Страница 11: ...o the beginning of the menu digital input configuration Operation Programming Operating the T600MSP 2 Once the T600MSP 2 thermostat is configured through the Installer Configuration Menu the thermosta...

Страница 12: ...does not appear Answering YES to this prompt enables the T600MSP 2 thermostat to resume the regular scheduled program and setpoints Schedule set Y N To resume the schedule while in the Main User Menu...

Страница 13: ...setpoints remain in effect for the duration set in the Temporary Occupancy Time parameter TOccTime or until manually released To release the temporary setpoint sooner while in the main User Menu 1 An...

Страница 14: ...ys changes the time in 1 minute increments Holding the keys down changes the time in 30 minute increments Note Programming one of the digital inputs to remote NSB disables the menu Follow the steps in...

Страница 15: ...e scheduling menu Press YES to set the schedule for Monday or NO to advance to Tuesday Press YES to set the occupied start time for Monday or NO to advance to Tuesday selecting NO leaves the thermosta...

Страница 16: ...press YES to store the time 4 Press YES to enter the day set menu or NO to enter the clock format menu 5 Use the UP DOWN arrow keys to adjust the day When the correct day is displayed press YES to st...

Страница 17: ...al Accessories Includes Mounting Hardware 2 Use the UP DOWN arrow keys to locate the desired permanent hold type or resume schedule Press YES to enter the choice Item Product Code Number Remote Indoor...

Страница 18: ...pment has been tested and found to comply with the limits for a Class A digital device and verified to Class B pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protecti...

Отзывы: