Setup and Adjustments 

Thermostat Operation Overview 

75.0ºF

Backlit, plain text, Liquid
Crystal Display (LCD)
is easy to read in any
condition.

Five keys on the T600
make operation easy
and intuitive.

Light Emitting Diodes (LEDs)
indicate system activity.

Room Temp

T

6

0

0

_

T

E

C

_

F

ro

n

t_

C

o

v

e

r

 

Figure 6: T600MSP-2 Thermostat Front Cover 

Thermostat Interface Keys 

The T600MSP-2 thermostat interface consists of 
five keys on the front cover and one configuration 
key (Figure 7) that is accessed by removing the 
front cover. Use the: 

• 

YES/SCROLL key to: 

− 

confirm menu selections, and to advance to 
the next menu item 

− 

stop the Status Display Menu from scrolling 
and to manually scroll to the next parameter 
on the menu. When left unattended for 
45 seconds, the display resumes scrolling. 

• 

NO key when you do not desire a parameter 
change, and to advance to the next menu item 

• 

MENU key to access the Main User Menu or exit 
the menu 

• 

UP/DOWN arrow keys to: 

− 

adjust values 

− 

activate a Temporary Setpoint 

 

Configuration

Key

T

6

0

0

_

T

E

C

_

C

o

n

fi

g

_

K

e

y

 

Figure 7: Configuration Key Location 

Backlit Liquid Crystal Display (LCD) 

The T600MSP-2 thermostat uses a two-line, 
eight-character backlit display. Low level backlighting 
is present during normal operation and it brightens 
when any user interface key is pressed. The backlight 
returns to the lower level when the thermostat is left 
unattended for 45 seconds. 

Light-Emitting Diodes (LEDs) 

Three LEDs are used to indicate the status of the fan, 
call for heat, or call for cooling. When: 

• 

the fan is on, the FAN LED lights up 

• 

heating is on, the HEAT LED lights up 

• 

cooling is on, the COOL LED lights up 

Programming Overview 

There are three menus used to view, program, and 
configure the T600MSP-2 thermostat: Status Display, 
Main User, and Installer Configuration Menus. 

4    

T600MSP-2 Programmable Thermostat Installation Instructions 

Содержание T600MSP-2

Страница 1: ...t cover Figure 1 2 Unlock the Printed Circuit Board PCB by carefully pressing the locking tab to the right Figure 2 Open the thermostat s PCB to the left 3 Pull out approximately 6 in 152 mm of wires...

Страница 2: ...s and reinsert on to the new thermostat To wire the thermostat 1 Strip each wire 1 4 in 6 35 mm and connect to the appropriate terminal according to the wiring diagram Figure 5 2 Gently push excess wi...

Страница 3: ...the selected fan mode 24 VAC from equipment transformer 24 VAC common from equipment transformer 24 VAC for heating stages Energizes on a call for first stage heating Energizes on a call for second s...

Страница 4: ...and to advance to the next menu item MENU key to access the Main User Menu or exit the menu UP DOWN arrow keys to adjust values activate a Temporary Setpoint Configuration Key T600_TEC_Config_Key Fig...

Страница 5: ...ver and press the CONFIG key from the Status Display Menu to enter the Installer Configuration Menu Configures Digital Input 1 Default No Function None See the Configuring the Digital Inputs DI1 and D...

Страница 6: ...hen the message displays the backlight momentarily lights up TOccTime set Y N Each digital input can be programmed in one of five conditions None No function is associated with the input Service A Ser...

Страница 7: ...e the Enabling Frost Protection Frost pr section for setup instructions Enabling Frost Protection Frost pr Frost protection establishes a minimum heating setpoint of 42 F 5 5 C to prevent freezing in...

Страница 8: ...rature control but could accelerate the wear of mechanical components in the equipment To set the maximum number of heating cycles per hour while in the Installer Configuration Menu 1 Answer NO to all...

Страница 9: ...emporary setpoint is entered The range is adjustable from 0 to 12 hours To change the temporary occupancy time while in the Installer Configuration Menu 1 Answer NO to all prompts until the temporary...

Страница 10: ...lue The display now shows the cooling lockout prompt See the Setting the Cooling Lockout C lock section for instructions Setting the Cooling Lockout C lock This feature disables cooling operation base...

Страница 11: ...o the beginning of the menu digital input configuration Operation Programming Operating the T600MSP 2 Once the T600MSP 2 thermostat is configured through the Installer Configuration Menu the thermosta...

Страница 12: ...does not appear Answering YES to this prompt enables the T600MSP 2 thermostat to resume the regular scheduled program and setpoints Schedule set Y N To resume the schedule while in the Main User Menu...

Страница 13: ...setpoints remain in effect for the duration set in the Temporary Occupancy Time parameter TOccTime or until manually released To release the temporary setpoint sooner while in the main User Menu 1 An...

Страница 14: ...ys changes the time in 1 minute increments Holding the keys down changes the time in 30 minute increments Note Programming one of the digital inputs to remote NSB disables the menu Follow the steps in...

Страница 15: ...e scheduling menu Press YES to set the schedule for Monday or NO to advance to Tuesday Press YES to set the occupied start time for Monday or NO to advance to Tuesday selecting NO leaves the thermosta...

Страница 16: ...press YES to store the time 4 Press YES to enter the day set menu or NO to enter the clock format menu 5 Use the UP DOWN arrow keys to adjust the day When the correct day is displayed press YES to st...

Страница 17: ...al Accessories Includes Mounting Hardware 2 Use the UP DOWN arrow keys to locate the desired permanent hold type or resume schedule Press YES to enter the choice Item Product Code Number Remote Indoor...

Страница 18: ...pment has been tested and found to comply with the limits for a Class A digital device and verified to Class B pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protecti...

Отзывы: