background image

SPECIFICATION DATA

Put Bar Code Here

63-4375ES—02

T6811/6812 Series Digital Thermostat

2-PIPE FAN COIL CONTROL

FEATURES

• Sleek modern design, suitable for office, hotel and 

residential buildings

• Large LCD display with English and icon display
• Easy to install and set-up
• Selectable room temperature or setpoint display
• Manual fan speed selection
• Adjustment of display room temperature
• Temperature display in either °C or °F
• Permanent memory retention
• Keypad Lockout
• Heat and cool range stops for energy savings

APPLICATION

T6811/6812 digital thermostats are designed for application of 

3-speed fans and valves in 2-pipe fan coil systems.

The T6811/6812 work for the following applications:

— 2-pipe cool only

— 2-pipe heat only

— 2-pipe heat/cool manual changeover

— Ventilation mode

— Manual 3-speed fan control

— Water valve control

Technical Specifications

Power Supply:

T6811DP08: 110(+20%,-10%)VAC

T6812DP08: 220(+/-10%)VAC

Frequency: 

50/60Hz.

Input Current: 

4 Amps Resistive/2 Amps Inductive

Control Algorithm: 

PI, On/off output

Accuracy: 

+/-1°C at 21°C

Rating Capacity:

220V: 4(2)A for fan load, 2(1)A for zone valve

110V: 4(2)A for fan load, 2(1)A for zone valve

Cycle Times: 

100,000

Setpoint Range: 

10°C to 32°C (50°F to 90°F)

Installation:

Installed on 86x86mm junction box or 2x4 inch junction box.

Protection Class: 

IP20

Environmental Conditions:

Operating temperature: -18°C to 49°C (0°F to 120°F)

Shipping temperature: -35°C to 65°C (-31°F to 149°F)

Relative humidity: 5 to 90%, non-condensing

Action Type: 

Action Type 1

Maximum Temperature for Relay Wiring: 

155°C (311°F)

Dimensions: 

(Fig. 1)

Fig. 1. Dimensions in in. (mm).

Table 1. Model summary.

Model

2-pipe/

4-pipe

Operating 

Voltage (V)

Remote 

Setback Ventilation

T6812DP08 2-pipe

220

N

Y

T6811DP08 2-pipe

110

N

Y

3-13/32 (86)

5

(126)

M29689A

Содержание T6811 Series

Страница 1: ...n mode Manual 3 speed fan control Water valve control Technical Specifications Power Supply T6811DP08 110 20 10 VAC T6812DP08 220 10 VAC Frequency 50 60Hz Input Current 4 Amps Resistive 2 Amps Inductive Control Algorithm PI On off output Accuracy 1 C at 21 C Rating Capacity 220V 4 2 A for fan load 2 1 A for zone valve 110V 4 2 A for fan load 2 1 A for zone valve Cycle Times 100 000 Setpoint Range ...

Страница 2: ... Setup If keypad lockout is chosen all of the keys will be disabled from use Ventilation Mode Press mode button to enter ventilation mode While in ventilation mode there will be no output for the valve but the fan will support manual fan speed control Terminal Designations Wiring Diagrams Fig 3 Typical wiring for ON OFF control in 2 pipes Heat Cool 1H1C For 2 wire valve actuators Fig 4 Typical wir...

Страница 3: ...e ventilación Control manual del ventilador de 3 velocidades Control de la válvula para agua Especificaciones técnicas Suministro de energía T6811DP08 110 20 10 V CA T6812DP08 220 10 V CA Frecuencia 50 60 Hz Consumo de corriente 4 Amps resistivos 2 Amps inductivos Algoritmo de control PI salida de encendido apagado Exactitud 1 C a 21 C Capacidad nominal 220V 4 2 A para la carga de ventilador 2 1 A...

Страница 4: ...tones Modo de ventilación Oprima el botón de modo para ingresar al modo de ventilación En el modo de ventilación no habrá salida para la válvula pero el ventilador permite el control manual de su velocidad Designaciones de los terminales Diagramas de cableado Fig 3 Cableado típico para control de ENCENDIDO APAGADO en calor frío 1H 1C a 2 tubos para actuadores de válvula de 2 cables Fig 4 Cableado ...

Отзывы: