www.johnsonandstarley.co.uk
30
21.
DEFECT DIAGNOSIS FOR THE CIRCULATION AIR FAN
21.1 CIRCULATION AIR FAN
21.1.1 Ensure Air Circulation Fan is running at maximum.
21.1.2 A voltage should be measured and blue (-) and yellow (+). Voltage approx. 10 VDC.
21.1.3 If voltage is present and fan is not running at maximum. Replace ACF.
Содержание WARMCAIR C26D
Страница 29: ...29 Sales Spares Replacement Help Line 01604 762881 20 FAULT FINDING FLOW CHART...
Страница 42: ...NOTES...
Страница 43: ...NOTES...