background image

ALL TECHNICAL AND WARRANTY QUESTIONS: 

SHOULD BE DIRECTED TO THE LOCAL DEALER FROM

WHOM THE WATER HEATER WAS PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WRITE TO THE
COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER.

GAMA certification applies to all

residential gas water heaters with

capacities of 20 to 100 gallons

with input rating of 75,000

BTU/Hr. or less.

Do not store or use gasoline or other

flammable vapors and liquids in the vicinity

of this or any other appliance.

–WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not

use any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas suppli-

er’s instructions.

• If you cannot reach your gas supplier, call

the fire department.

Installation and service must be performed

by a qualified installer, service agency or

the gas supplier.

WARNING: If the information in these

instructions are not followed exactly, a fire

or explosion may result, causing property

damage, personal injury or death.

Improper installation, adjustment, alteration,

service or maintenance can cause DEATH,

SERIOUS BODILY INJURY, OR PROPERTY

DAMAGE. Refer to this manual for assistance

or consult the local gas utility for further

information.

WARNING

Flammable vapors may be drawn by air cur-

rents from other areas of the structure to this

appliance.

WARNING

READ THE GENERAL SAFETY SECTION

BEGINNING ON INSIDE COVER AND THEN

THIS ENTIRE MANUAL BEFORE INSTALLING

OR OPERATING THIS WATER HEATER.

WARNING

Save this Manual for Future Reference.

For Your Safety

AN ODORANT IS ADDED TO THE GAS

USED BY THIS WATER HEATER

Instruction Manual for 

Residential 

Gas Water Heaters

NOT FOR USE IN MANUFACTURED (MOBILE) HOMES

184115-000

0

3

-03

Содержание Hydroheat A650YRRTL5

Страница 1: ...epartment Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or death Improper installation adjustment alteration service or maintenance can cause DEATH SERIOUS BODILY INJURY OR PROPERTY DAMAGE Refer to ...

Страница 2: ...ce If odor is detected follow steps indicated at For Your Safety on the cover page of this manual then leave the premises WARNING Improper installation adjustment alteration service or mainte nance can cause DEATH SERIOUS BODILY INJURY OR PROP ERTY DAMAGE Refer to this manual or consult your local gas utility for assistance WARNING At the time of manufacture this water heater was provided with a c...

Страница 3: ...equate air supply to avoid risks of improper operation explosion or asphyxiation General Safety WARNING Obstructed or deteriorated vent systems may present a serious health risk or asphyxiation WARNING Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors Spray can propellants cleaning solvents refrigerator and air conditioner refrige...

Страница 4: ... Lighting 14 15 Temperature Regulation 16 For Your Information 17 18 Start Up Conditions 17 Draft Hood Operation 17 Condensation 17 Smoke Odor 17 Thermal Expansion 17 Strange Sounds 17 Operational Conditions 17 18 Smelly Water 17 Air In Hot Water Faucets 18 High Temperature Shut Off System 18 Not Enough or No Hot Water 18 Water Is Too Hot 18 Periodic Maintenance 18 20 Venting System Inspection 18 ...

Страница 5: ... reading this manual you have any questions or do not understand any portion of the instructions call the local gas utility or the manufacturer whose name appears on the rating plate Preparing for the New Installation 5 4 Carefully plan the place where you are going to put the water heater Correct combustion vent action and vent pipe installation are very important in preventing death from possibl...

Страница 6: ...ll satisfy space heating clothes washing dish washing and other sanitizing needs can scald and permanently injure you upon contact Some people are more likely to be permanently injured by hot water than others These include the elderly children the infirm or physically mentally handicapped If anyone using hot water in your home fits into one of these groups or if there is a local code or state law...

Страница 7: ... be accomplished in such a manner that if the tank or any connections should leak the flow of water will not cause damage to the structure For this reason it is not advisable to install the water heater in an attic or upper floor When such locations cannot be avoided a suitable drain pan should be installed under the water heater Drain pans are available at your local hardware store Such a drain p...

Страница 8: ...inches of the top and one commencing within 12 inches from the bottom of the enclosure The openings shall communicate direct ly or by ducts with the outdoors or spaces crawl or attic that freely communicate with the outdoors 1 When directly communicating with the outdoors each opening shall have a minimum free area of 1 square inch per 4 000 Btu per hour of total input rating of all equip ment in ...

Страница 9: ...ater inlet It will harm the dip tube and damage the tank Installing the New Water Heater Water Piping 9 WARNING HOTTER WATER CAN SCALD Water heaters are intended to produce hot water Water heated to a temperature which will satisfy clothes washing dish washing and other sanitizing needs can scald and permanently injure you upon contact Some people are more likely to be permanently injured by hot w...

Страница 10: ...quire a valve model different from the one furnished with the water heater Compliance with such local requirements must be satisfied by the installer or end user of the water heater with a local ly prescribed temperature pressure relief valve installed in the designated opening in the water heater in place of the factory furnished valve For safe operation of the water heater the relief valve must ...

Страница 11: ...nal Fuel Gas Code ANSI Z223 1 also referred to as NFPA 54 11 Venting CAUTION Never use this water heater unless it is completely full of water To prevent damage to the tank the tank must be filled with water Water must flow from the hot water faucet before turning ON gas to the water heater WARNING To insure proper venting of this gas fired water heater the correct vent pipe diameter must be utili...

Страница 12: ... cleaning solvents refrigerator and air conditioner refrigerants swimming pool chemicals calcium and sodium chloride waxes bleach and process chemicals are typical compounds which are potentially corrosive WARNING Make sure the gas supplied is the same type listed on the model rating plate The inlet gas pressure must not exceed 10 5 in water column 2 6kPa for natural gas or 13 in water column 3 2k...

Страница 13: ...er heater and anything that might catch fire See the Locating the New Water Heater section 7 Do you have adequate ventilation so that the water heater will operate properly See Combustion Air and Ventilation in the Locating the New Water Heater section 8 Is the draft hood vent piping properly secured See Venting instructions in the Installing the New Water Heater section 9 Is there proper clearanc...

Страница 14: ...ore attempting to light or relight the water heater s pilot or turning on a nearby electrical light switch be absolutely sure there is no accumulated gas in the area Search for odor of gas by sniffing at ground level in the vicinity of the appliance If odor is detected follow the steps indicated at For Your Safety on the cover page of this manual then leave the premises WARNING AN ODORANT IS ADDED...

Страница 15: ...e on this label If you don t smell gas go to the next step 6 Remove or open inner door located below the gas control unit Figure 9 7 Find pilot follow metal tube from gas control The pilot is located in front of the burner 8 If you don t smell gas turn knob on gas control counter clockwise to PILOT position Figure 7 9 Push in control knob all the way and hold down Immediately light the pilot with ...

Страница 16: ...ashing and other sanitizing needs can scald and perma nently injure you upon contact Some people are more likely to be permanently injured by hot water than others These include the elderly children the infirm or physical ly mentally handicapped If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the...

Страница 17: ... equipped with an internal by pass and no other measures are taken the devices cause the water system to be closed As water is heated it expands thermal expansion and closed systems do not allow for the expansion of heated water The water within the water heater tank expands as it is heated and increases the pressure of the water system If the relieving point of the water heater s temperature pres...

Страница 18: ...o heat the water and seem like less hot water 9 If you cannot find what is wrong call the local gas utility and or plumbing contractor WATER IS TOO HOT 1 The temperature adjustment dial may be set too high See the Temperature Regulation section NOTE A period of time is necessary after an adjustment has been made for the water temperature to reach the new temperature setting 2 If lower temperature ...

Страница 19: ... AND BURNER ASSEMBLY REPLACEMENT INFORMATION For Propane L P Gas Models Only Your water heater is equipped with a Propane L P gas control valve and a main burner assembly with left hand threads for the following fittings and their connections 1 The connection between the manifold and the gas control valve A to B are left hand threads 2 The connection between the main burner orifice and the manifol...

Страница 20: ...r from any claim which might result from excessive temperature or pressure Temperature Pressure Relief Valve Operation The temperature pressure relief valve must be manually operated at least once a year 20 HANDLE AND CAP ASSEMBLY TEMPERATURE PRESSURE RELIEF VALVE DISCHARGE PIPE WASHER WARNING When checking the temperature pressure relief valve operation make sure that 1 no one is in front of or a...

Страница 21: ... the floor This is common at the time of startup after installation and when incoming water is cold Water in the water heater bottom or on the floor may be from condensation loose connections or the relief valve DO NOT replace the water heater until a full inspection of all possible water sources is made and necessary corrective steps taken Leakage from other appliances water lines or ground seepa...

Страница 22: ...e model number of your Gas Water Heater will be found on the rating plate located above the gas control valve WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION MODEL NUMBER TYPE GAS NATURAL OR PROPANE L P SERIAL NUMBER PART DESCRIPTION THIS IS A REPAIR PARTS LIST NOT A PACKING LIST KEY NO PART DESCRIPTION 1 Temperature Pressure Relief Valve 2 Primary Anode Rod 3 Drain Valve 4 Drain ...

Страница 23: ...Notes 23 ...

Страница 24: ......

Отзывы: