4.
SAFETY & GAS INFORMATION
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE COMMENCING WITH
THE INSTALLATION
4.1 GENERAL SAFETY INFORMATION
4.1.1
Ensure the mains supply voltage, frequency, number of phases and power rating comply
with details on the rating label.
4.1.2
All wiring must be in accordance with the appropriate standards. The equipment must
be supplied with a double pole isolator switch.
4.1.3
Ensure safety regulations and practices are adhered to when installing and using this
equipment.
4.1.4
The weight of this appliance exceeds that recommended for a one-man lift. It will
therefore be necessary to gain assistance at times during the installation procedure.
4.1.5
It should be noted that this appliance may contain sharp edges. Care MUST be taken
when handling the appliance to prevent injury.
4.1.6
Once the appliance has been fired, beware that certain parts will be hot to the touch.
4.1.7
Do not install flues during rain, high winds or in severe weather conditions.
4.2 GAS INFORMATION
4.2.1 Gas Categories
a. The appliance is certified as a CAT I 2H (20) appliance.
4.2.2 Gas Supply
a. The gas installation must be completed in accordance with the relevant standards
(BS 6891).
b. The supply must be capable of providing a steady inlet working pressure to the
appliance of 20 mbar at a rate of 1.94 m³/h or 52.64 ft²/h (Calculated with a Gas C of
38.7 MJ/m³)
c. The installation must be tested for gas tightness using suitable methods. The
Pipework should also be purged of air in accordance with the IG Publication Standard.
5.
TECHNICAL DATA
TABLE 1. C26D TECHNICAL DATA
C26D
WEIGHT
68 kg
GAS
G20
GAS SUPPLY PRESSURE
20 mbar
GAS CATEGORY
I2H
COUNTRIES OF INSTALLATION
United Kingdom and Ireland
ELECTRICAL SUPPLY
250V ~ 50Hz fused 5A 530 Watts
ELECTRIC POWER CONSUMPTION
100 W (at rated heating capacity), 27 W (at minimal cap.), 5 W (standby mode)
USEFUL EFFICIENCY
88% (at rated heating capacity), 88% (at minimum capacity)
ENVELOPE LOSS FACTOR
0
IGNITION BURNER POWER CONSUM.
0 W
EMISSIONS OF NITROGEN OXIDES
99 mg/kWh
EMISSION EFFICIENCY
84.69 %
SEASONAL SPACE HEATING ENERGY EFFIC.
73.98 %
MAXIMUM
MINIMUM
kW
MJ/h
Btu/h
kW
MJ/h
Btu/h
INPUT (GROSS)
26
93.6
88,712
8
28.8
27,296
OUTPUT
22.88
82.37
78,066
7.04
25.34
24,020
GAS RATE CV 1037 Btu/FT³
2.42 m³/h (85.54 ft³/h)
0.74 m³/h (26.32 ft³/h)
BURNER % CO²
9 ± 1
8 ± 1