FIGURE 5. TERMINAL POSITIONS
TABLE 2. TERMINAL DIMENSIONS
TERMINAL POSITION
MINIMUM DISTANCE
A
Directly below an opening, air brick, opening window, etc.
300 mm
B
Above an opening, air brick, opening window, etc.
300 mm
C
Horizontally to an opening, air brick, opening window, etc.
300 mm
D
Below gutters, soil pipes or drain pipes.
75 mm
E
Below eaves.
200 mm
F
Below balconies.
200 mm
G
From a vertical drain pipe or soil pipe.
150 mm
H
From an internal or external corner. Greater than 450 mm protrusion.
300 mm
I
Above ground, roof or balcony level.
300 mm
J
From a surface facing the terminal.
600 mm
K
From a terminal facing the terminal.
1,200 mm
M
Vertically from a terminal on the same wall.
1,500 mm
N
Horizontally from a terminal on the same wall.
300 mm
Q
Above intersection with roof.
530 mm
P
From a vertical structure on the roof.
300 mm
R
From the terminal to the boundary.
300 mm