Chapter 2 Diagnostic Codes
2-26
900
Power fail detected
950
OPTImA hardware main board fault detected
951
OPTImA hardware inner scanner fault detected
952
OPTImA hardware outer scanner fault detected
953
OPTImA hardware rear scanner fault detected
9FF
ERROR_SELFTEST
e01
ASA: Status of an activated order has changed due to network manager or shop
management software activities.
2.10 IBP CODES
Error ID
Error tag
Equivalent
Y2K error
Hofmann
User error
001-001
BK_ERROR_PO_NOTFOuND
internal
-
001-002
BK_ERROR_PO_READING
internal
-
001-003
BK_ERROR_PO_WRITING
new
-
001-004
BK_ERROR_PO_EEP1_RD
internal
-
001-005
BK_ERROR_PO_EEP2_RD
internal
-
001-006
BK_ERROR_PO_EEP1_WR
new
-
001-007
BK_ERROR_PO_EEP2_WR
new
-
001-010
BK_ERROR_KBD_DISPLAy
internal
-
001-011
BK_ERROR_KBD_vOLTAGE
46x-xxx
-
001-012
BK_ERROR_KBD_READING
46x-xxx
-
001-020
BK_ERROR_DC_OvERRuN
xxx-401
E83
001-021
BK_ERROR_IEm_ZERO_mISmATCH
290-703
-
001-022
BK_ERROR_IEP_ZERO_mISmATCH
2A0-703
-
001-030
BK_ERROR_POWER_FAIL
xxx-900
-
001-031
BK_ERROR_TEmP_SENSOR
xxx-58x
-
001-032
BK_ERROR_vCC_ABOvE_LImIT
xxx-811
-
001-033
BK_ERROR_vCC_BELOW_LImIT
xxx-810
-
001-034
BK_ERROR_vDISP_ABOvE_LImIT
xxx-821
-
001-035
BK_ERROR_vDISP_BELOW_LImIT
xxx-820
-
001-036
BK_ERROR_LINE_ABOvE_LImIT
xxx-801
-
001-037
BK_ERROR_LINE_BELOW_LImIT
xxx-800
-
001-038
BK_ERROR_OPTO_SHORT_HIGH_CuR
xxx-708
-
001-039
BK_ERROR_OPTO_OPEN_LOW_CuR
xxx-707
-
001-040
BK_ERROR_SAPE_1D_LOW_vOLT
xxx-350
E92
001-041
BK_ERROR_SAPE_1D_HIGH_vOLT
xxx-351
E92
001-042
BK_ERROR_SAPE_2D_LOW_vOLT
xxx-360
E92
Содержание EEWB304B
Страница 1: ...WHEEL BALANCER Service Manual EEWB502B C EEWB503B EEWB304B ...
Страница 56: ......