Checkout and maintenance
1-20
DIAMETER sApE / pOTENTIOMETER VpI II, III IV &
sOT LD
• Disconnect the power from the rear of the machine.
• Remove the Display panel.
• Remove the weight tray.
• Disconnect the 2D SAPE harness from the main Proces
-
sor Board.
• Remove the 10mm nut holding the SAPE wheel to the
mounting bracket and slide the cog wheel off of the poteti
-
ometer shaft.
• Remove the 13mm nut holding the potentiometer to the
frame.
• Reverse procedure for installation.
DIAMETER sApE / pOTENTIOMETER ADJUsTMENT
• Install 5K potentiometer onto bracket and tighten 13mm
nut.
• Install cog wheel onto potentiometer shaft and hand
tighten 10mm nut.
• Attach SAPE harness to Power Supply Board.
• With the SAPE arm in the home position program <
F/p
>
<51>.
• Pull out the SAPE arm and rest it on the vibratory tube
(Figure 3-32), using a flatblade screwdriver turn the poten
-
tiometer to a voltage reading of
3.10vDC +/- .05.
• Run <
F/p
/C> <80> for SAPE calibration.
sApE gAUgE
• To remove the index finger, remove the phillips screw from
the backside of the gauge.
• To remove the SAPE arm remove the phillips screw that
attaches to the distance rod.
• To remove the distance rod, disconnect the diameter string
from the end of the rod.
• Slide the distance rod completely out.
• Reverse procedure for installation.
Содержание EEWB304B