Checkout and maintenance
1-9
F/P 80 SAPE GAUGE CALIBRATION
To calibrate the SAPE gauge.
make sure the SAPE arm is in the home position as
1.
shown in (80-1).
NOTE: WEIGHT TRAY MUST BE INSTALLED
Activate the gauge calibration program. Press and re
-
2.
lease the
<F/p>
key, turn the shaft until the display reads
“
F/p
” 80 is displayed on right display window and press
enter.
The right display will read
3.
"CAL” “3-D” “sAp"
for one
second (Do not move the arm at this point) this means
CALibration SAPE. Then it displays
"sAp” “OUT”
“FUL”
. The SAPE calibration procedure is activated.
Gently pull the SAPE arm OuT until it is fully extended
4.
(80-2), hold it steady for about 1 second, a tone will
sound.
Display will read
5.
“bAC” “H” “pOs”
followed by a beep.
Return the arm to the home position.
NOTE: STEP 5 IS THE FINAL STEP FOR A VPI SYS-
TEM I BALANCER.
Display changes to
6.
“dIA” “ -18” “pOs”
.
Gently pull the SAPE out and rest the arm of the SAPE
7.
gauge on the bell housing (80-3). A tone will sound and
the display will change to
“bAC” “H” “pOs”
.
Return the arm to the home position. The display will
8.
change to
“dIA” “42.1” “pOs”
.
Locate the Calibration Weight. Place the calibration
9.
weight with the large end oriented on the bell collar.
Extend the SAPE arm outward and rotate the extension
to just touch the end of the calibration weight (80-4). A
tone will sound and the display will change to
“bAC” “H”
“pOs”
. Return the SAPE arm to the home position.
NOTE: THE REMAINING STEPS APPLY ONLY TO THE
VPI SYSTEM III BALANCER.