Chapter 2 Diagonostic Codes
2-3
2.3 SELF-TEST DuRING START-uP (CRT/HNA/HWT)
A series of tests is accomplished after the machine has been turned on. If a test is not successful:
a series of audible signals is given, or
•
an error code is read out.
•
On HNA/HWT or CRT models, a three-tone signal is given once, if the machine is operative.
In case there is a functional error it must be acknowledged by pressing the STOP or ESC key and there is no
three-tone signal.
1.
Communication between microcontroller and embedded PC
Blue screen
Affected models : CRT models
Service Codes : No service code available
Communication between micro-controller and embedded PC is not OK (check serial cables).This can
also indicate a bad connection to the keyboard.
2.
Check home position of left SAPE
E3
Affected models : models with 1D-, 2D-SAPE or geodata
Service Codes : C80 (& C81) to calibrate SAPE
C92 to check distance and diameter of actual calibration
Inner SAPE gauge arm not in home position.Re-place SAPE gauge arm in home position and press
STOP or ESC key to continue.
3.
Check home position of right SAPE
E4
Affected models : models with 3D-P-SAPE
Service Codes : C82 to calibrate SAPE
Outer SAPE gauge arm not in home position.Re-place SAPE gauge arm in home position and press
STOP or ESC key to continue.
4.
Check weights usage database
E50
Affected models : models with AWP
Service Codes : C125 to format the weights usage database
An attempt to access the weights usage database has failed; restart the balancer to re-initialise the data
-
base, or call service if the problem persists
5.
Power clamp service interval expired
E85
Affected models : models with power clamp
Service Codes : All codes available for the model
6.
Check Keyboard
E89
Affected models : All models
Service Codes : No service code available
One of the keys F1 to F6, HELP, ESC, START supplies a key code. The machine will proceed with the
next step only if the trouble is remedied.
7.
Check Pedal switches
E85
Affected models : models with power clamp or electromagnetic brake
Service Codes : C56 to check the pedal switches.
C75, AdC16 to check voltage to external switches
models with solenoid brake only and power clamp:One or, if available, both pedal switches are actuated.
The user can now remedy the trouble. Press STOP or ESC key to check the pedal switch once again and
to delete the error code reading. If the trouble cannot be remedied, the pedal is made inoperative.