Chapter 2 Diagnostic Codes
2-6
-
there is a fault in the inner scanner CCD board
-
there is a fault in the camera controller board
-
the supply voltage is configured too high on the power interface board
Corrective actions:-
check all items above
-
switch power off and on again; should the problem not go away please call ser
-
vice
22.2
Check Optima inner scanner memory
E371
Affected models : models with optima hardware
Service Codes : C123
Possible causes: -
the flat cable connecting the camera controller board and the inner scanner CCD
board is unplugged, missing or damaged
-
there is a fault in the inner scanner CCD board
-
there is a fault in the camera controller board
Corrective actions:-
check the connections§ check the inner scanner CCD board
-
check the camera controller board
-
switch power off and on again; should the problem not go away please call ser
-
vice
22.3
Check Optima inner scanner memory
E372
Affected models : models with optima hardware
Service Codes : C123
Possible causes: -
the flat cable connecting the camera controller board and the inner scanner CCD
board is partially unplugged or damaged
-
there is a fault in the inner scanner CCD board
Corrective actions:-
check the connections
-
check the inner scanner CCD board
-
switch power off and on again; should the problem not go away please call ser
-
vice
22.4
Check Optima inner scanner calibration
E373
Affected models : models with optima hardware
Service Codes : C123
Possible causes: -
the inner scanner has not been factory calibrated
Corrective actions:-
please call service and replace the inner scanner
22.5
Check Optima inner motor power supply
E374
Affected models : models with optima hardware
Service Codes : C123
Possible causes: -
the cable connecting the camera controller board and the inner scanner motor is
unplugged, damaged or missing
-
the motor power supply is not configured properly
-
there is a fault in the motor power supply board
-
the cable connecting the mains supply and the motor power supply board is
unplugged, damaged or missing
-
there is a fault in the inner scanner motor
-
there is a fault in the camera controller board motor drivers
Corrective actions:-
check all items above
22.6
Check Optima inner scanner zero mark
E375
Affected models : models with optima hardware
Service Codes : C123
Possible causes: -
the flat cable connecting the camera controller board and the inner scanner CCD
board is unplugged, missing or damaged
-
there is a fault in the inner scanner CCD board
-
the inner scanner is locked
-
the inner scanner zero mark is missing, bent, locked or damaged
-
the cable connecting the camera controller board and the inner scanner motor is
unplugged, damaged or missing