Chapter 2 Diagnostic Codes
2-14
sERVICE CODEs
2.4 H CODES (CRT/HNA/HWT)
ui_error.h revision 1.11
H
Internal code(s)
Description
0
H0
Wheel running conditions cannot be improved by optimisation
H1
Further optimisation not recommended but feasible
H2
Weight minimization is recommended, optimisation can achieve no further
improvement
20
H20
The correction plane cannot be re-located using the gauge arm
H21
Indexing position does not match correction plane
H22
0x492215
unclamping of power clamp device is disabled
H23
unclamping of wheel not allowed
H26
The gauge arm was pulled out too quickly (normal operation, ASS calibra
-
tion)
H28
NEW : The gauge arm was pulled out too slowly (ASS calibration)
80
H80
0x810510
No provision was made for readjustment
H82
Self test disturbed during execution
90
H90
0x492203,
- acceleration during start or stop too slow- measuring speed not reached
H91
0x492204
Speed too low during measuring run
Содержание EEWB304B
Страница 1: ...WHEEL BALANCER Service Manual EEWB502B C EEWB503B EEWB304B ...