Checkout and maintenance
1-13
F/P 88 TDC CALIBRATION
mount the Pruefrotor on the balancer shaft and enter in the
1.
parameters of the Pruefrotor using the balance screen.
Press and release the
2.
<F/p>
key, turn the shaft until the
display reads “
F/p
” “88” is displayed. The display changes
to “CAL” “ANG” for one second. Press the <START> but
-
ton to begin the measurement run.
F/P 84 EMPTY SHAFT CALIBRATION PROCEDURE
Press and release the
1.
<F/p>
key, turn the shaft until the display reads “
F/p
” “84” is displayed. The display
changes to “CAL” “SHF” for one second.
Then it displays “SPN” “1“.
2.
Spin the empty shaft by pressing the <ENTER> button or lower the hood.
3.
The board displays the following information.
4.
• Displays “CAL” “ 1” when the shaft reaches calibration speed. The machine is taking data and doing
calculations. After taking data, shaft is automatically braked to a stopped. Then displays
“CAL” “SHF” “FIN” for one second. The machine displays the shaft resident unbalances in fine mode. The
fine mode LED indicator is automatically on.
• By pressing <STOP> key to exit F84 and return to idle state. The fine mode
LED indicator is automatically turned off.
NOTE: UNITS WITH A POWER CLAMP REQUIRE A SPACER (EAM-
0033D53A) BE INSTALLED BETWEEN THE CONE AND CLAMPING
SLEEVE AND A SECOND SPIN CYCLE BE COMPLETED.
Attach the 100 gram weight to outside of the Pruefrotor and
3.
press the <START> button.
After the shaft comes to a complete stop rotate the shaft to
4.
locate the 100 gram weight at “BOTTOm DEAD CENTER”
position. Press the <ENTER> key F6 (Optima/BFH) or
press the <F/P> button digital balancers to save the data.
CALIBRATION COMpLETE