Chapter 2 Diagonostic Codes
2-15
2.5 E CODES (CRT/HNA/HWT)
ui_error.h revision 1.11
E
Internal code(s)
Description
0
E1
Rim dimensions entered incorrectly
E2
Wheel guard is not closed
E3
Gauge arm not in home position
E4
Outer gauge arm not in home position
E5
Range of electrical unbalance compensation exceeded (residual adapter
unbalance)
E6
0x812560,
0x812561,
0x812565,
0x812566
Calibration weight not attached to flange
E7
No balancing mode for this wheel type
E8
valve position was not entered
E9
Optimisation was carried out incorrectly
10
E10
Wheel guard is not open, wheel may not be clamped / unclamped
E12
Not available to
date
Pedal is operated, measuring run not possible
E13
Not available to
date
The clearance of the solenoid brake is too wide.
E14
The power clamping device is not clamped
E15
Corrective terms for readjustment are out of range
E16
0x812570,
0x812571
Calibration weight attached erroneously to flange
E17
0x492207
Wheel slipped on adapter
20
E28
0x492205
Wrong direction of rotation (hand spin)
E29
Speed too high (hand spin ?)
30
E30
Run-out measurement failed
E31
Rim only mounted during geometric matching when rim and tyre expected.
E32
The user selected to proceed with a bare rim measurement but the ma
-
chine actually detects that a complete wheel is on the machine. mount a
bare rim.
50
E50
An attempt to access the weights usage database has failed; restart the
balancer to re-initialise the database, or call service if the problem persists
80
E83
vibration of the machine disturbed the unbalance measurement
E85
Power clamp service interval expired
E88
0x492208
The rotating speed of the main shaft exceeds the safety limit
E89
Key contact or pedal switch closed
Содержание EEWB304B
Страница 1: ...WHEEL BALANCER Service Manual EEWB502B C EEWB503B EEWB304B ...
Страница 56: ......