Joerns Support Surface

Arise

®

 LAL Mattress Replacement,  

Arise LAL Overlay, Arise 1000, Arise 1000EX

Therapy Pads

Many healthcare facilities are facing the challenge 
of infection control. Joerns’ quilted therapy pads 
are treated with an antimicrobial to protect the 
therapy pad from the growth of mold, mildew  
and bacteria.

Key features and benefits:

Treated with a highly effective bacteriostat 
agent to inhibit the growth of bacterial  
and fungus
Constructed from a very smooth nylon fabric 
with low friction and low shear properties 
to protect the patient’s skin from damaging 
friction/shearing forces
Breathable, moisture vapor permeable  
fabric allows air to circulate beneath the  
pad and wicks away excess moisture. This 
keeps your patient dry and helps to prevent 
skin maceration. 
Therapy pad is designed for optimal comfort, 
moisture vapor transfer, stain resistance and 
ease of laundering.

Grounding Instructions

 

Warning:

 Use a properly grounded, three-

prong, 120V AC outlet for this product. Failure 
to use a grounded outlet could result in personal 
injury or damage to equipment or house wiring, 
including risk of fire. A qualified electrician should 
be contacted to correct the wiring and ensure a 
properly grounded outlet.

Before installing this product, have the electrical 
system checked to make sure the electrical circuits 
and the electrical service are properly grounded.

Having a three-prong outlet does not necessarily 
mean it is grounded. Sometimes two-prong outlets 
are replaced with a three-prong type even though 
there is no ground wire. 

There is always a chance of a loose connection 
or poor installation of a ground wire that causes 
the loss of proper ground at the outlet. Inadequate 
grounding at electrical outlets can occur even if 
there is a ground wire. Wires can become loose 
over time at the connection to the outlet.

Note:

 To install new wires on a circuit requires a 

qualified electrician.

 

8

How to Determine if Your Outlet has 

the Proper Grounding

Most hardware stores sell circuit testers 
(Figure 1) that can be used to test an 
outlet for proper grounding. The tester 
plugs into an outlet and by observing  
the indicator lights you can determine  
if the outlet is properly grounded. For a 
higher level of assurance, an electrician 
should be requested to thoroughly test 
the electrical system with more  
reliable equipment.

 

If repair or replacement of the cord or plug is 
necessary, please contact Joerns Healthcare  
for assistance.

Setup

Warning:

 For important precautions please see  

page two.

Caution: 

Do not place the control unit on the floor. 

Position the power cord to keep personnel from 
tripping over it.

Comfort Adjust Setup

Fully inflate the mattress by selecting 

Autofirm

When the mattress is fully inflated, select the 

Therapy

 mode, and place the patient on  

the mattress.

Select the appropriate 

Comfort Adjust

 level to 

prevent bottoming out (i.e., providing greater than 

one inch of air between the patient’s sacral  

area/buttocks and the lower safety mattress) as 

outlined below:

Begin by placing the head of the bed in the 

appropriate position based on the patient’s 

clinical condition. 

Select the highest or most firm 

Comfort  

Adjust

 setting.

Hand Check: Place a hand with three (3) 

fingers (if head of bed at 30° or higher) or 

four (4) fingers (if head of bed lower than 

30°) stacked vertically beneath the cells of 

the mattress and above the safety mattress 

directly between the lowest point of the 

patient’s sacral area/buttocks. The  

smallest finger should be resting on  

the safety mattress. 

1.

2.

3.

Figure 1

Electronic Copy: Reference Only

Содержание arise1000

Страница 1: ...r Service Manual Joerns Support Surface Arise LAL Mattress Replacement Arise LAL Overlay Arise 1000 Arise 1000EX transforming wound management To avoid injury read user s manual before using Electroni...

Страница 2: ...stem always ensure that the patient is positioned properly within the confines of the bed Do not let any extremities protrude over the side or between the bed rails when the mattress is being used Dan...

Страница 3: ...aps and spaces between bed system components and clinical guidance for assessment and implementation of bed side rails in various health care settings Entrapment zones involve the relationship of bed...

Страница 4: ...and Monitoring Additional Features 12 13 CPR Transport Power Failure CairRails Optional Accessories Troubleshooting 13 Therapy Surface Not Inflating Unable to Change Therapy Mode or Adjust Comfort Con...

Страница 5: ...from these damaging forces 5 Introduction The Arise provided by Joerns Healthcare is a unique therapy system that provides pressure relief by combining low air loss with pulsation Low air loss therap...

Страница 6: ...l times The use of the Arise for these patients should be considered on an individual basis and discussed with the attending physician Features The Arise is comprised of two components Therapy control...

Страница 7: ...ut for most patients within weight limit Integrated low pressure heel section provides lower interface pressures Durable base tub is constructed from 100 heavy weight 1680 denier nylon with a 1 5 oz u...

Страница 8: ...proper ground at the outlet Inadequate grounding at electrical outlets can occur even if there is a ground wire Wires can become loose over time at the connection to the outlet Note To install new wir...

Страница 9: ...lls facing up Secure the straps around the head and foot ends of the mattress Fasten the two straps by the seat section securely to the sleep deck of the bed frame 4 5 If the therapy pad is not alread...

Страница 10: ...flated as required Locate the control knob Figure 2 on the lower right of the control panel on the mattress Next inflate deflate the CairRails by moving the control knob to the up inflate or down defl...

Страница 11: ...urn to the mode it was in prior to Autofirm either therapy or pulsate in approximately 12 minutes The Arise has two low air loss therapy modes Therapy and Pulsate Therapy The unit starts in the Therap...

Страница 12: ...to twenty 20 minutes The power interruption feature keeps the current settings in memory based on the frequency of use and level of battery charge The Alarm Reset will turn off audible and visual alar...

Страница 13: ...ke sure the Lockout function is disabled To disable press the up and down comfort adjust arrows simultaneously 1 2 3 4 Nursing Procedures Recommended Linen Special linens are not necessary for the Ari...

Страница 14: ...s Early intervention may be essential to preventing serious skin breakdown Bed Height To minimize the risks of falls or injury the patient surface should always be in the lowest practical position whe...

Страница 15: ...warm water no more than 120 Fahrenheit A non bleach detergent should be used sparingly Wipe dry or allow to air dry Steam Cleaning Do not use any steam cleaning device on the unit Excessive moisture...

Страница 16: ...8 122 cm W 80 203 cm H 8 5 22 cm D Arise 1000EX Mattress 36 42 48 91 107 122 cm W 80 88 203 224 cm L 8 5 22cm D Electrical Specifications USA 120V AC 60 Hz 4A less than 1A running Environmental Condit...

Страница 17: ...www joerns com info joerns com Joerns Support Surface Arise LAL Mattress Replacement Arise LAL Overlay Arise 1000 Arise 1000EX 17 Notes Electronic Copy Reference Only...