Important Precautions 

Important Notice: 

The equipment must be 

installed and operated in the manner for which 
it was intended. Facility staff/user is responsible 
for reading and understanding the product user 
manual and contacting Joerns if anything in 
this manual is unclear. Joerns will not be held 
responsible for any injuries resulting from failure 
to comply with the instructions and precautions in 
this manual.

Warning:

 

Joerns Healthcare’s specialty support 

surfaces are designed as mattress replacement 
systems and overlays. The risk of entrapment 
may occur when the equipment is placed on 
bed frames or mattresses that leave gaps of 
even a few inches between the mattress and the 
headboard, footboard, and bed or side rails.  
The equipment is NOT to be used when such  
gaps are present. 

Facility staff/user is responsible for ensuring 
that all mattresses and overlays properly fit 
the bed frames. Joerns is not responsible for 
the placement of its equipment on bed frames 
that leave gaps between the mattress and the 
headboard, footboard or bed or side rails which 
present a risk of harm to patients.

Warning:

 An optimal bed system assessment 

should be conducted on each patient by a qualified 
clinician or medical provider to ensure maximum 
safety of the patient. The assessment should be 
conducted within the context of and in compliance 
with the state and federal guidelines related to 
the use of restraints and bed system entrapment 
guidance, including the 

Clinical Guidance for the 

Assessment and Implementation of Side Rails

 

published by the Hospital Bed Safety Workgroup 
of the U.S. Food and Drug Administration. Further 
information can be obtained at the following web 
address: http://www.fda.gov/cdrh/beds/.

When using the mattress system, always ensure 
that the patient is positioned properly within the 
confines of the bed. Do not let any extremities 
protrude over the side or between the bed rails 
when the mattress is being used.

Joerns Healthcare 1_Art Direction_Joerns Beds_700 Series_UltraCare 8page
5/2007_Page 2 of 8

Danger Explosion Hazard:

 Do not use in the 

presence of flammable anesthetics. Do not use    
in the presence of smoking materials or open  
flame. Air flowing through the air mattress will 
support combustion.

Danger:

 To reduce the risk of shock, adhere to the 

following instructions. Failure to do so could result in 
personal injury or equipment damage.

Immediately after using the Arise

®

, unplug it from 

its power source.
Do not place or store the product where it can 
fall or be pulled into a tub or sink.
Do not place or drop the product into water or 
other liquid.
Do not remove the back of the control unit. Refer 
servicing to Joerns Healthcare.

Warning:

 To reduce the risk of burns, shock, fire, or 

personal injury, adhere to the following instructions. 
Failure to do so could result in personal injury or 
equipment damage.

Use this product only for its intended purpose as 
described in this manual. Only use attachments 
and/or accessories that are recommended by 
the manufacturer.
If this product has a damaged power cord or 
plug, is not working properly, has been dropped 
or damaged, or has been dropped into water, do 
not operate it. For examination and repair, return 
the product to Joerns.
Keep the control unit and power cord away from 
heated surfaces, e.g. space heaters.
Never block the air openings of the product. Do 
not place the control unit on a surface, such as a 
bed or couch, where the air opening and/or filter 
compartment, located on the back of the control 
unit, may be blocked. Keep the air openings free 
of lint and hair.
Never drop or insert any object into any opening 
or hose. 
Do not spill food or liquids onto the control 
unit. If a spillage does occur, turn off the unit, 
disconnect it from its power supply and allow at 
least 24 hours for drying.
Do not use the product outdoors, or where 
aerosol-spray products are used.

1.

2.

3.

4.

1.

2.

3.

4.

5.

6.

7.

2

Electronic Copy: Reference Only

Содержание arise1000

Страница 1: ...r Service Manual Joerns Support Surface Arise LAL Mattress Replacement Arise LAL Overlay Arise 1000 Arise 1000EX transforming wound management To avoid injury read user s manual before using Electroni...

Страница 2: ...stem always ensure that the patient is positioned properly within the confines of the bed Do not let any extremities protrude over the side or between the bed rails when the mattress is being used Dan...

Страница 3: ...aps and spaces between bed system components and clinical guidance for assessment and implementation of bed side rails in various health care settings Entrapment zones involve the relationship of bed...

Страница 4: ...and Monitoring Additional Features 12 13 CPR Transport Power Failure CairRails Optional Accessories Troubleshooting 13 Therapy Surface Not Inflating Unable to Change Therapy Mode or Adjust Comfort Con...

Страница 5: ...from these damaging forces 5 Introduction The Arise provided by Joerns Healthcare is a unique therapy system that provides pressure relief by combining low air loss with pulsation Low air loss therap...

Страница 6: ...l times The use of the Arise for these patients should be considered on an individual basis and discussed with the attending physician Features The Arise is comprised of two components Therapy control...

Страница 7: ...ut for most patients within weight limit Integrated low pressure heel section provides lower interface pressures Durable base tub is constructed from 100 heavy weight 1680 denier nylon with a 1 5 oz u...

Страница 8: ...proper ground at the outlet Inadequate grounding at electrical outlets can occur even if there is a ground wire Wires can become loose over time at the connection to the outlet Note To install new wir...

Страница 9: ...lls facing up Secure the straps around the head and foot ends of the mattress Fasten the two straps by the seat section securely to the sleep deck of the bed frame 4 5 If the therapy pad is not alread...

Страница 10: ...flated as required Locate the control knob Figure 2 on the lower right of the control panel on the mattress Next inflate deflate the CairRails by moving the control knob to the up inflate or down defl...

Страница 11: ...urn to the mode it was in prior to Autofirm either therapy or pulsate in approximately 12 minutes The Arise has two low air loss therapy modes Therapy and Pulsate Therapy The unit starts in the Therap...

Страница 12: ...to twenty 20 minutes The power interruption feature keeps the current settings in memory based on the frequency of use and level of battery charge The Alarm Reset will turn off audible and visual alar...

Страница 13: ...ke sure the Lockout function is disabled To disable press the up and down comfort adjust arrows simultaneously 1 2 3 4 Nursing Procedures Recommended Linen Special linens are not necessary for the Ari...

Страница 14: ...s Early intervention may be essential to preventing serious skin breakdown Bed Height To minimize the risks of falls or injury the patient surface should always be in the lowest practical position whe...

Страница 15: ...warm water no more than 120 Fahrenheit A non bleach detergent should be used sparingly Wipe dry or allow to air dry Steam Cleaning Do not use any steam cleaning device on the unit Excessive moisture...

Страница 16: ...8 122 cm W 80 203 cm H 8 5 22 cm D Arise 1000EX Mattress 36 42 48 91 107 122 cm W 80 88 203 224 cm L 8 5 22cm D Electrical Specifications USA 120V AC 60 Hz 4A less than 1A running Environmental Condit...

Страница 17: ...www joerns com info joerns com Joerns Support Surface Arise LAL Mattress Replacement Arise LAL Overlay Arise 1000 Arise 1000EX 17 Notes Electronic Copy Reference Only...

Страница 18: ...www joerns com info joerns com Joerns Support Surface Arise LAL Mattress Replacement Arise LAL Overlay Arise 1000 Arise 1000EX 18 Notes Electronic Copy Reference Only...

Страница 19: ...www joerns com info joerns com Joerns Support Surface Arise LAL Mattress Replacement Arise LAL Overlay Arise 1000 Arise 1000EX 19 Notes Electronic Copy Reference Only...

Страница 20: ...authorized in writing by Joerns Healthcare will void this warranty Damage caused by use in unsuitable environmental conditions abuse or failure to maintain the product in accordance with user and serv...

Отзывы: