Joerns Support Surface

Arise

®

 LAL Mattress Replacement,  

Arise LAL Overlay, Arise 1000, Arise 1000EX

Pressure Relief

The Arise is divided into three distinct anatomical 
zones: head, seat, and foot. Each zone is adjusted 
to ensure optimal pressure relief and provide a 
comfortable sleeping surface. 

Maximum pressure relief is achieved through 
delivering a specific amount of air to each therapy 
cell and allowing controlled amounts of air to 
escape, thus equalizing the pressure between 
the patient and the therapy cells. This distributes 
the patient’s weight evenly over a wide surface 
area resulting in average pressure readings below 
capillary closure levels.

Moisture Control

Patients are at risk for skin maceration if excess 
moisture is permitted to accumulate beneath 
the patient. This may be due to perspiration, 
incontinence or wound drainage. 

 

On the Arise, moisture is controlled via the 
specially treated breathable, fluid-proof, urethane 
coated nylon therapy pad. The moisture vapor 
permeable fabric of the therapy pad allows a 
sufficient amount of air to circulate beneath the 
pad and wicks away excess moisture.

Shear and Friction Reduction

Shearing occurs when the skin is stationary 
in relation to the support surface, while the 
underlying tissues and vessels are stretched and 
damaged. When a patient’s skin rubs against 
another surface, the result is friction. The top 
surface of the Arise therapy pad is constructed 
from a very smooth nylon fabric with low friction 
and shear properties to protect the patient’s skin 
from these damaging forces.

Joerns Healthcare 1_Art Direction_Joerns Beds_700 Series_UltraCare 8page

4/2007_Page 5 of 8

5

Introduction

The Arise

®

, provided by Joerns Healthcare, is a 

unique therapy system that provides pressure relief 
by combining low air loss with pulsation. Low air 
loss therapy has been demonstrated to reduce the 
risk of pressure ulcers as well as being a valuable 
aid in the treatment of pressure ulcers. The Arise is 
available as a mattress replacement system and as 
a mattress overlay. 

Warning:

 The risk of entrapment can develop when 

equipment is placed on bed frames that leave gaps 
of even a few inches between the mattress and the 
headboard, footboard, and bed or side rails. The 
equipment is NOT to be used when such gaps are 
present. See “Important Precautions” section of   
this manual.

The Arise mattress replacement systems and 
overlays are suitable for both the treatment of 
existing pressure ulcers Stage I through Stage IV as 
well as those who have been assessed at risk from 
the complications of immobility. The Arise is quiet, 
comfortable and simple enough for single caregiver 
installation, featuring rapid inflation in just three to 
five minutes. The user-friendly controls allow for 
easy adjustment of patient comfort. The Arise offers 
special features to increase peace of mind such as 
a power interruption alarm and a patient position 
sensor which optimizes support for seated patients 
(Fowler Boost).

Additionally, low friction and shear materials, 
together with average interface pressures below 
capillary closure levels (32mm of Mercury),  
means that the Arise meets the comfort and  
clinical requirements.

We have ensured that the Arise addresses the four 
key areas in the treatment of compromised skin: 
pressure relief, moisture control, and reduction in 
both friction and shearing forces.

Electronic Copy: Reference Only

Содержание arise1000

Страница 1: ...r Service Manual Joerns Support Surface Arise LAL Mattress Replacement Arise LAL Overlay Arise 1000 Arise 1000EX transforming wound management To avoid injury read user s manual before using Electroni...

Страница 2: ...stem always ensure that the patient is positioned properly within the confines of the bed Do not let any extremities protrude over the side or between the bed rails when the mattress is being used Dan...

Страница 3: ...aps and spaces between bed system components and clinical guidance for assessment and implementation of bed side rails in various health care settings Entrapment zones involve the relationship of bed...

Страница 4: ...and Monitoring Additional Features 12 13 CPR Transport Power Failure CairRails Optional Accessories Troubleshooting 13 Therapy Surface Not Inflating Unable to Change Therapy Mode or Adjust Comfort Con...

Страница 5: ...from these damaging forces 5 Introduction The Arise provided by Joerns Healthcare is a unique therapy system that provides pressure relief by combining low air loss with pulsation Low air loss therap...

Страница 6: ...l times The use of the Arise for these patients should be considered on an individual basis and discussed with the attending physician Features The Arise is comprised of two components Therapy control...

Страница 7: ...ut for most patients within weight limit Integrated low pressure heel section provides lower interface pressures Durable base tub is constructed from 100 heavy weight 1680 denier nylon with a 1 5 oz u...

Страница 8: ...proper ground at the outlet Inadequate grounding at electrical outlets can occur even if there is a ground wire Wires can become loose over time at the connection to the outlet Note To install new wir...

Страница 9: ...lls facing up Secure the straps around the head and foot ends of the mattress Fasten the two straps by the seat section securely to the sleep deck of the bed frame 4 5 If the therapy pad is not alread...

Страница 10: ...flated as required Locate the control knob Figure 2 on the lower right of the control panel on the mattress Next inflate deflate the CairRails by moving the control knob to the up inflate or down defl...

Страница 11: ...urn to the mode it was in prior to Autofirm either therapy or pulsate in approximately 12 minutes The Arise has two low air loss therapy modes Therapy and Pulsate Therapy The unit starts in the Therap...

Страница 12: ...to twenty 20 minutes The power interruption feature keeps the current settings in memory based on the frequency of use and level of battery charge The Alarm Reset will turn off audible and visual alar...

Страница 13: ...ke sure the Lockout function is disabled To disable press the up and down comfort adjust arrows simultaneously 1 2 3 4 Nursing Procedures Recommended Linen Special linens are not necessary for the Ari...

Страница 14: ...s Early intervention may be essential to preventing serious skin breakdown Bed Height To minimize the risks of falls or injury the patient surface should always be in the lowest practical position whe...

Страница 15: ...warm water no more than 120 Fahrenheit A non bleach detergent should be used sparingly Wipe dry or allow to air dry Steam Cleaning Do not use any steam cleaning device on the unit Excessive moisture...

Страница 16: ...8 122 cm W 80 203 cm H 8 5 22 cm D Arise 1000EX Mattress 36 42 48 91 107 122 cm W 80 88 203 224 cm L 8 5 22cm D Electrical Specifications USA 120V AC 60 Hz 4A less than 1A running Environmental Condit...

Страница 17: ...www joerns com info joerns com Joerns Support Surface Arise LAL Mattress Replacement Arise LAL Overlay Arise 1000 Arise 1000EX 17 Notes Electronic Copy Reference Only...

Страница 18: ...www joerns com info joerns com Joerns Support Surface Arise LAL Mattress Replacement Arise LAL Overlay Arise 1000 Arise 1000EX 18 Notes Electronic Copy Reference Only...

Страница 19: ...www joerns com info joerns com Joerns Support Surface Arise LAL Mattress Replacement Arise LAL Overlay Arise 1000 Arise 1000EX 19 Notes Electronic Copy Reference Only...

Страница 20: ...authorized in writing by Joerns Healthcare will void this warranty Damage caused by use in unsuitable environmental conditions abuse or failure to maintain the product in accordance with user and serv...

Отзывы: