Figure 71. Clear Drive of Failed Status
• Drive fails due to a system fault.
Select a replacement drive: If a drive fails during system operation, it
will be marked as a failed drive. This drive is most likely damaged
and not a good choice for a rebuild. It should physically be replaced
or the rebuild option should be directed to a different drive already
installed. In order to start a manual rebuild, click on the Select a
replacement drive button on the Rebuild window, (see
and
Figure 72. Select the Replacement Drive Button
Manual Rebuild Process
This section assumes three conditions: 1- that a hard disk drive is already
installed and available in your enclosure, 2- that there are no global or dedicated
spares assigned, 3- that auto rebuild in not enabled. The following instructions
will walk you through a manual rebuild process of an array.
Once a member drive has failed, it will be marked with a circled X and displayed
in the Physical Elements Panel, but is no longer part of any array (see
(it is not included in the highlighted blue drives (ComArray1)). This will cause
the associated array to be marked as degraded with a yellow tag (see
If the auto rebuild does not start immediately (no global or dedicated spare
available), you will need to manually direct the system to rebuild an array set.
MARLIN
TM
4-39
M
MA
AR
RLLIIN
N
T
TM
M
16-Bay 4G FC-SATA300/SAS RAID Array Management Users Guide Rev B
Click the following:
1) failed drive
2) Clear Failed Status