JJ-CCR ApS 2017
www.JJ-CCR.com
2017 JJ-CCR ApS – 2.00 / Revision 06
87
Info Screens
Description
CC and BO mode
Ext V:
Indicates the current voltage of the battery for the solenoid un-
der load in volts. When not under load, the value may be incorrect and
much too high, providing an entirely inaccurate picture of the battery
condition. If, in place of a value a ”
?
” is displayed then this shows that
the solenoid has not yet been actuated and the controller has been
unable to carry out any measurement. If the voltage of the batteries is
very low then the value is displayed in
red
.
Int V:
Shows the current voltage of the controller battery in volts. The
value is displayed in
yellow
if the battery is almost empty and requires
replacing. If the value is displayed in
red
then the battery voltage is
critical and the battery should be replaced immediately.
CC and BO mode
Surf:
Shows the surface pressure in mBar. The pressure is measured
when switched on, and saved until the controller is switched off again. If
the automatic altitude adjustment is switched off (altitude = SeaLvl) then
1013 mBar is always displayed. The value is generally only displayed at
the surface. This means when the controller is not in dive mode.
Now:
Shows the current ambient pressure in mBar. This value is also
displayed in dive mode.
CC and BOmode
Date:
Displays the current date (day/month/year)
Time:
Displays the current time (hh/mm)
CC and BO mode
Serial No:
Shows the controller serial number.
Version:
Shows the model and firmware version of the controller. The last
two digits stand for the installed firmware version.