![JJ-CCR CE Edition Скачать руководство пользователя страница 105](http://html1.mh-extra.com/html/jj-ccr/ce-edition/ce-edition_user-instructions_2018669105.webp)
JJ-CCR ApS 2017
www.JJ-CCR.com
2017 JJ-CCR ApS – 2.00 / Revision 06
105
14 Maintenance
As with all technical equipment, the JJ-CCR Rebreather should always be treated with care. General care
also includes observing the maintenance intervals and regularly checking the general condition of the
equipment. For example, the O-ring grease.
If the maintenance intervals are observed, there is theoretically no given maximum service life. However,
the user should be aware that rubber and plastic parts do age, and that this process is accelerated by
exposure to direct sunlight. If these parts are not replaced during standard maintenance works then the
following maximum service life figures apply:
The following care products can be used:
Decisive here is the production year of the equipment. This information can be found on the type plate.
For example ”Mfg Date: 11/07” stands for the year 2011 and the month of July. If the parts have not been
replaced at an earlier date during maintenance then they must be replaced no later than upon reaching
this date. Exceptions here are the oxygen sensors. In this case a service life of one year applies from the
date of production printed on them.
14.1 General Care
14.2 Maximum Service Life
14.3 Approved care products
Service life
Part(s)
10 years
All rubber parts – Breathing hose, mouthpiece, O-rings, etc.
10 years
Counter lungs – without outer liners
10 years
Diluent hoses – High pressure and middle pressure
5 years
Oxygen hoses – High pressure and middle pressure
1 year
Oxygen sensors (Max. operating life after installation)
Care product
Description
Grease
Molykote 111:
Can be used for greasing all breathing circuit elements.
ChristoLube MCG 111, Tribolube 71 or Halocarbon 25-5S:
Can be used for greasing all
breathing circuit elements and all parts conducting at medium pressure.
Desinfection
Virkon S, Steramine 1G or CHEMGENE HLD4L
Follow the directions for use supplied with the disinfectant used.
Cleaning
For general cleaning (e.g. after use in seawater) normal tap water should be used.