Push both the HUD and the controller through the handle.
Take both breathing hoses and feed these through
the handle. Afterwards, your equipment should be
in position as in the image above.
Note:
The breathing hose in the centre of the lid
is for the inhalation side and is always connected
to the ADV!
Now connect the oxygen low pressure
hose.
Only tighten until hand-tight!
Connect the breathing hoses to the T-piece and
ADV. It is not possible to connect these incorrectly
because the two connection threads are different.
The connection thread on the inhalation side (ADV)
is clockwise, whilst the thread on the exhalation
side (T-piece) is anti clockwise.
ATTENTION:
Never attempt to lift the equipment
using the ADV or T-piece. This can cause serious
damage to the counter lungs!