6.19 Setpoint -> .19
This menu item is only displayed in surface mode. It allows to switch to
a setpoint of .19 whilst the controller is on the surface. This prevents
the solenoid from being permanently active. The function is mainly used
during a firmware upgrade or when uploading dives.
6.20 System Setup
Using this menu item it is possible to access a range of submenus for the
basic configuration of the controller. This menu item, as well as all of the
submenus contained within it, are unavailable in dive mode. As such, ba-
sic configuration of the controller can only be carried out at the surface.
Various options such as ”Low and High Setpoint” or ”NDL Display” can
also be found in the dive menu and can therefore be retrospectively ad-
justed as necessary when underwater.
All settings (basic settings, gases used, etc) can therefore be implemented
quickly and easily prior to the dive. If necessary, it is also possible to make
adjustments underwater via the dive setup menu, as previously described.
It is essentially irrelevant whether settings are adjusted in the dive menu
or within the system setup submenu! It is always the same values that are
changed. If, for example, the diver sets the low SP in the dive setup to 0.8
then this value will also be displayed under low SP in the dive menu. If the
diver changes this value back to 0.7 in the dive menu then this value will
also be adjusted in the dive setup.
The system setup submenus are grouped into various areas. All of the settings relevant to one area can
be viewed on a single screen.
•
The 0.19 setpoint is not intended for use when breathing on the loop!
•
When setpoint .19 is selected the center row diplays a yellow warning
“Setp = .19” above the PPO2 readings.
•
The solenoid injection is very aggressive when the 0.19 setting is active.
Switching to the normal setpoint takes place in the ”Switch SP” menu.
Mode Setup
Deco Setup
CC Gases
BO Gases
O2 Setup
System Setup
Auto SP Switch
Display Setup
Compass
System Setup
Advanced Config