6.20.37
Gas Select
(Advanced Config 1)
The ”Advanced Config“ page 2 allows the changing of the PPO2 limits.
WARNING:
Do not change these values unless you understand the effect
•
A ”Low PPO2“ or ”High PPO2“ alert is displayed when the limits are
violated for more than 30 seconds.
Setting
Description
OC Min. PPO2
PPO2 displays in flashing
red
when less than this value. The default is 0.19.
OC Max. PPO2
PPO2 displays in flashing
red
when higher than this value. The default is 1.65.
OC Deco PPO2
The decompression predictions (TTS and NDL) will assume that the gas in use at a given depth
is the gas with the highest PPO2 that is less than or equal to this value. Also, the suggested gas
switches (when the current gas is displayed in
yellow
) are determined by this value. If you change
this value, please understand its effect. For example, if lowered to 1.50, then oxygen (99/00) will not
assumed at 6m. The default is 1.61.
CC Min PPO2
PPO2 displays in flashing
red
when less than this value. The default is 0.40.
CC Max. PPO2
PPO2 displays in flashing
red
when higher than this value. The default is 1.60.
6.21 Bus Devices
The “Bus Devices” info screen shows a
list of all DiveCan® devices. It also allows
changing settings on peripheral boards. For
example, on the SOLO board (solenoid and
oxygen controller) the Solenoid Speed set-
ting can be adjusted.
6.20.38
Advanced Config 2
(Overview)
This option allows to change the stile of the “Select Gas” menu. You can
choose between the “Classic” and “New” stile. The classic stile shows one
gas with a big font. The new stile shows all gases at the same time with a
small font. Please refer to chapter 7 for a detailed description.