Surface Mode
In surface mode the user is able to set both gradient factors (low and high).
Dive Mode
In dive mode the user is only able to set the high gradients.
Using this menu item it is possible to set the con-
servatism for the calculation of the decompres-
sion based on gradient factors (low and high).
Two different modes are available here:
•
These settings can have a massive effect on the decompression calculations of the controller!
•
If the diver does not know what effects these settings will have, no setting adjustments should be made
for safety reasons!
•
In order to understand the settings the diver must be aware of the theory of the gradient factors,
M-values, inert gas pressure, etc!
A range of articles on this subject can be found on the internet. The article by Eric C. Baker can be rec-
ommended in particular.
If the settings are to be changed (edit mode) then it is necessary to push the right button ”Edit”.
Pressing the right button ”Save” saves the current settings. Editing mode is closed and the user switches
to the next menu item.
First the low gradient factor is set (visible
at the ”GF Lo” display). Only one digit of
the number is changed at a time. The ten’s
are always set first. Pressing the left but-
ton ”Change” results in the displayed digit
being increased by 1. After the digit has
reached 9 it will revert back to 0 again.
Pressing the right button ”Next” once takes
the diver to the units digit.
Now the high gradient factor is set (visi-
ble at the ”GF Hi” display). Only one digit
of the number is changed at a time. The
ten’s are always set first. Pressing the left
button ”Change” results in the displayed
digit being increased by 1. After the digit
has reached 9 it will revert back to 0 again.
Pressing the right button ”Next” once takes
the diver to the units digit.