P/N 960-100175R_Rev. 6 {EDP #200824}
© 2016, JAPAN CASH MACHINE CO., LTD.
1 - 7
General Information
Taiko™ Series Banknote Acceptor
Section 1
E
LECTRICAL
S
PECIFICATIONS
S
TRUCTURAL
S
PECIFICATIONS
System Configuration
Figure 1-11 illustrates a typical Taiko™ PUB-7/11 system configuration.
Table 1-4
Taiko PUB-7/11 Electrical Specifications
Supply Voltage
*
:
*. 12V DC = 7-Pin, 24V DC = 9-Pin.
12V DC ±5%/24V DC ±10%
†
†. 24V DC is available only when the optional 24V DC Specification is used.
Current Consumption
‡
:
‡. Use the CLASS 2 Limited Power Source.
Standard Specification
Standby = 0.1A [12V DC]/0.1A [24V DC]
Operation = 0.5A [12V DC]/0.5A [24V DC]
Maximum = Approximately 1.4A (Maximum of 300ms) [12V DC]/
Approximately 1.0A (Maximum of 300ms) [24V DC]
Barcode Specification
Standby = 0.1A [12V DC]
Operation = 0.6A [12V DC]
Maximum = Approximately 1.6A (Maximum of 300ms) [12V DC]
**
**.Motor Initializing or Motor Lock Up current consumption.
Table 1-5
Taiko PUB-7/11 Structural Specifications
Weight:
Approximately 0.6kg (1.3 lbs)
Mounting
*
:
*. Allow 3.93 inches (100mm) above the Unit for opening the Lid and Bezel removal.
Horizontal (on door - non vibrating)
Outside Dimensions:
See “Taiko PUB-7 Standard Bezel Unit Outside Dimensions” on page 1-8
of this Manual.
Cash Box:
User prepared
†
†. Cash Box must be 3.93 inches (100mm) or more in depth from the bottom of the TAIKO Unit, 7.87 inches (200mm) or more in depth from the Unit rear
and 3.93 inches (100mm) or more in width.
Taiko PUB-7/11 System Configu-
Figure 1-11
Taiko PUB-7/11 System Configuration
a
b
c
f
e
d
Maintenance Connector
Interface
Connector
Communications
Harness
a) Taiko™ PUB-7/11 Unit
b) PC (Windows 98SE/2000/XP)
c) JCM Power Supply Unit (EDP# 116125)
d) Taiko™ Harness B (EDP# 116488: for old I/F) or
Taiko™ Harness B (EDP# 127527: for new I/F)
e) Taiko™ Harness A (EDP# 121797)
f) Host Machine (Gaming, Vending, etc.)
NOTE: The Communications Harness needs to be prepared by the Customer.
Taiko™ Harness B (EDP# 127527: for new I/F) is included in the JCM Power Supply Unit.