Calibration and Testing
Taiko™ Series Banknote Acceptor
Section 6
No.4 Solenoid Test Procedure
The Solenoid Test detects the Solenoid’s normal
operating condition. Proceed as follows to perform
a Solenoid Test:
1. Set DIP Switch No. 1, 2, 3 and 4
ON
and supply
the Power to the Taiko™ Unit.
2. Set DIP Switch No.1 to
OFF
to begin the Test.
The Taiko™ Unit will begin the following test
operation:
–
The Entrance Flapper will operate ON &
OFF, then
–
The Exit Flapper operates ON & OFF.
The Front Panel LED will light
Blue
indicating the
Test is complete and no error was detected.
No.5 Acceptance Test Procedure
The Acceptance Test detects the proper presence of
inserted Banknotes. Proceed as follows to perform
an Acceptance Test:
1. Set DIP Switch No.1 and No.5
ON
and supply the
Power to the Taiko™ Unit.
2. Set DIP Switch No.1 to
OFF
to begin the Test.
3. Insert a Banknote into the Taiko™ Unit. If the
Banknote is returned the
Red
or
Yellow
LED will
flash a specific number of times indicating the
return error condition. Table 6-5 lists the flash
counts and the related error condition.
No.6 Entrance Flapper Test Procedure
The Entrance Flapper Test detects proper Entrance
Flapper operation. Proceed as follows to perform
an Entrance Flapper Test:
1. Set DIP Switches No. 1, 4 and 5
ON
and supply
the Power to the Taiko™ Unit.
2. Set DIP Switch No.1 to
OFF
to begin the Test.
The Taiko™ Unit will begin repeating the
Entrance Flapper open and close testing opera-
tion.
The
Blue
Front Panel LED will light indicating
the Test is complete and no error was detected.
No.7 Exit Flapper Test Procedure
The Exit Flapper Test detects proper Exit Flapper
operation. Proceed as follows to perform an Exit
Flapper Test:
1. Set DIP Switches No. 1, 2, 4 and 5
ON
and sup-
ply Power to the Taiko™ Unit.
2. Set DIP Switch No.1 to
OFF
to begin the Test.
The Taiko™ Unit will begin repeating the Exit
Flapper open and close testing operation.
The
Blue
Front Panel LED will light indicating
the Test is complete and no error was detected.
6
Left NIR Transmissive (Lower to Upper)
7
Right Blue Transmissive (Lower to Upper)
8
Left Blue Transmissive (Lower to Upper)
1
Right IR Transmissive (Upper to Lower)
2
Left IR Transmissive (Upper to Lower)
3
Right Red Transmissive (Upper to Lower)
4
Left Red Transmissive (Upper to Lower)
5
Right NIR Transmissive (Upper to Lower)
6
Left NIR Transmissive (Upper to Lower)
7
Right Blue Transmissive (Upper to Lower)
8
Left Blue Transmissive (Upper to Lower)
Table 6-4
Solenoid Error Codes
Red Flashes
Error Indicated
1
Entrance Solenoid not Energizing
2
Entrance Solenoid Energizing, but does not
release
3
Exit Solenoid not Energizing
4
Exit Solenoid Energizing, but does not Release
Table 6-3
Aging Test Error Codes (Cont.)
Flash No.
& Color
Sensor Location
WARNING: If the
Red
LED lights, the
Solenoid is faulty.
Table 6-5
LED Flash Error Codes
Red Flashes
Error Indicated
2
ROM Error
3
Banknote Jam inside Acceptor
4
Banknote Remaining in the Transport Path
5
Adjustment Error
6
Motor Error
8
Entrance Solenoid Error
9
Exit Solenoid Error
12
Sensor Operating with Abnormal Timing
1
Slanted Banknote Insertion Rejection
4
X-Rate Error
5
Banknote Transportation Error
7
Pattern Error
8
Photo Level Error
9
Inhibit Setting Value Rejection
13
Banknote Length Error
14
IR/Red Error
15
Counterfeit Currency Rejection
WARNING: If the
Red
LED lights, the
Entrance Flapper is faulty.
WARNING: If the
Red
LED lights, the Exit
Flapper is faulty.