P/N 960-100175R_Rev. 6 {EDP #200824}
© 2016, JAPAN CASH MACHINE CO., LTD.
6 - 4
Section 6
Taiko™ Series Banknote Acceptor Calibration
and
Testing
Refer to the applicable Software Information Sheet
to obtain the required cloning features Software.
C
LONING
P
ROCEDURES
Perform the steps to Clone a Taiko™ Unit:
1. Connect the Master Taiko™ Unit, the Slave
Taiko™ Unit, the Power Supply Unit and the
Harnesses as illustrated in Figure 6-5.
2. Set Master Taiko™ Unit DIP Switches #1, 2,7
and 8 to ‘
ON
’.
3. Set the Slave Taiko™ Unit DIP Switches #1, 7
and 8 to ‘
ON
’.
4. Confirm that the White LED on the Master
Taiko™ Unit is flashing, and that the
Green
LED
on the Slave Taiko™ Unit is also flashing.
5. Set Master Taiko™ Unit DIP Switch #1 ‘
OFF
’ to
begin the cloning process.
6. When cloning begins, the Master Taiko™ Unit’s
Front Panel LED will be a
Pink
Color, and the
Slave Taiko™ Unit LED will be a
Yellow
Color.
7. When the Slave Taiko™ Unit’s Front Panel LED
lights
Blue
(or flashes
Green
), the cloning pro-
cess is complete (after approximately 15 min-
utes).
8. Set the Master Taiko™ Unit’s DIP Switch #1 to
‘
ON
’ to end the cloning process.
9. When creating another Taiko™ Unit Clone, turn
the power to all of the Units OFF and re-connect
the next Slave Taiko™ Unit in place of the previ-
ously cloned Unit; then re-perform this procedure
from Step 2 again.
NOTE: See Figure A-1 on page A-5 to
identify each maintenance part number to
order.
NOTE: When the Taiko™ Unit is connected
to the Host Machine, the Power Supply Unit
and Taiko™ Harness “A” are not required.
Figure 6-5
Taiko Clone Software Tool Con-
Figure 6-5
Taiko Clone Software Tool Connection Configuration
To Slave
Maintenance Connector (4-Pin)
Interface Connector (10-Pin)
To Master
Maintenance
Connector
To Interface
Connector
To AC Power
ID-001
Interface
Connector
ID-003
ccTalk/Hll
Connector
To AC Power
a) Master Taiko™ Unit
b) Slave Taiko™ Unit
c) VM-450 Supply Unit
d) JCM Power Supply Unit or Equivalent
e) Host Machine
f) Clone Harness
g) VM-450 Harness
h) Taiko™ Harness “A”
i) Host Machine Harness (User prepared)
a
b
c
d
e
f
g
h
i
Maintenance
Connector
Maintenance
Connector
To Interface
Connector
To Interface
Connector