Page 9 / 41
Ref doc :
330740F/EN
revision 01
29.09.2015
3.2 Receiver RSRA
Housing
ABS, black/yellow
IP 40
Weight
495 g (approx.)
Dimensions
67 x 84 x 129mm (not including antenna)
Operating temperature range
0 °C to + 50 °C
Storage temperature range
- 30 °C to + 70 °C
Connection
Spring terminals for wires 0.08² to 2.5²
Characteristics compliant with ETS 300 220
Frequency
64 frequencies programmable in 433-434 MHz
Antenna
Sensitivity
< -100 dBm
Power supply voltage Un
24 VDC
Voltage range (at max., 5% ripple)
0.85 to 1.15 Un
Consumption
max., 120 mA (Static output, not loaded)
Contacts
3 NO
Type of contacts
Linked contact relays
Pull-in time at Un
Automatic start
800 ms max. (power up)
Automatic restart
70 ms max.
Manual start
110 ms max.
Trip time (reaction)
S12-S14, S22-S24, S32-S34
25 ms max.
Stop (remote control): 170 ms max.
Assigned output voltage
AC250V
Low voltage switching
> 100 mV
Thermal current Ith
5 A
Switching capacity
Per AC 15 :
AC 3A/230 V for NO contacts EN60947-5-1
AC 2A/230 V for NC contacts EN60947-5-1
Per DC 13 :
DC 8A/24 V at 0.1 Hz EN60947-5-1
Electrical service life
Per AC15 at 2A, AC230V
100 000 cycles EN60947-5-1
Short-circuit rating
Maximum fuse rating
6 A gL EN60947-5-1
Mechanical service life
10 x 10^6 cycles
Type of outputs
Static outputs, PNP
Nominal voltage Un (A3, A4)
DC 24 V
Voltage range
0.85 to 1.15 Un
Output voltage
DC 24V, max. 100mA thermal
max. 400 mA for 0.5s
Overload and temperature protection
Indicators
2 yellow indicator lights: state of safety module
2 red indicator lights: state of safety relays
1 green indicator light: radio reception quality
Radio characteristics
Electrical characteristics
1 red indicator light: wrong identity code or diagnostic
Secure relay outputs (terminals 13-14, 23-24, 33-34 or 31-32)
Static outputs (terminals 48, 58, 17, 27, 37, 47, 57, 67, 77)
1/4 wave, as accessory, plugs in to BNC connector
Mechanical characteristics and environmental withstand capacity