8.3.2 Procedure for programming « transmitter activity monitoring » duration.
Note : The product is supplied with the
“activity monitoring” duration set for 15 minutes.
Changing the counting unit
1-
- Push and hold button B1.
2
- Unlock the emergency stop palmswitch on the transmitter,
3
- Wait until the orange indicator goes off before releasing button B1.
The counting unit is indicated by the two indicator lights on the transmitter.
When ON, the orange indicator light indicates that the counting unit is in minutes.
When ON, the green indicator light indicates that the counting unit is in seconds.
4-
Select the new counting unit using button B2.
5-
Once the new counting unit is selected, press the
“On” button to validate your choice.
6-
Exit the programming mode by pressing the emergency stop palmswitch.
Setting the duration
1-
Switch off the receiver.
2-
Insert the electronic key in the transmitter.
3-
- Press and hold buttons B1 and "On
”,
- unlock the emergency stop palmswitch on the transmitter (Fig.1),
- Wait until the orange indicator goes off before releasing buttons B1 and "On".
The duration of the « activity monitoring » function is indicated by the two flashing indicator lights on the transmitter,
representing the tens (orange) and the units (green) of the number of minutes or seconds configured.
4-
Select the new duration using buttons B1 and B2 (Fig.2&3).
By pressing button B1, the tens are incremented, by pressing button B2, the units are incremented.
During these operations, the newly selected duration is indicated by the two indicator lights on the transmitter.
5-
Once the new duration is selected (between 01 and 99), press the “On” button to validate your choice (Fig. 4).
Caution, No. 99 corresponds to an infinite « activity monitoring » duration when the counting unit is in
« minutes
» (1) . When the counting duration is in “seconds”, the number 99 corresponds to 99 seconds.
> The function is then deactivated ; if you forget to stop the transmitter, it will discharge completely.
6-
Exit the « activity monitoring » duration programming mode by pressing the emergency stop palmswitch (Fig. 6).
(1) Caution: functioning mode without « activity monitoring » could be dangerous.
Be sure to indicate the new transmitter
“activity monitoring” duration on the key identification
sheet.