Page 23 / 41
Ref doc :
330740F/EN
revision 01
29.09.2015
Diagram for
“area access” by gate
Diagram for « area access » by safety barrier
A1+ S11 S12 S14 S13 S21 S22 S24 S23 S31 S32 S34 S33 S42 A3 A4 13 23 33 Y1 Y2
A2- 58 48 17 27 37 A2- 47 57 67 77 A2- 14 24 34
K1
K2
Red (1)
(Receiver error code)
Charger
contacts
Safety receiver
RSRA
27 to 77 : Control outputs of
radiocontrol function buttons
Emerg.
stop
24V DC
Orange (1)
Radio
transmitter
active
Green (1)
Equipment
operating
Detect transmitter on
charger
K3
K3
(1) Ind. light
column
Antenna
Start
button
Output
Input
Passage
request
BI
OSSD
Trans
mitter
A2 -
A5+
IR
K3 K4
A1+ S11 S12 S14 S13 S21 S22 S24 S23 S31 S32 S34 S33 S42 A3 A4 13 23 33 Y1 Y2
A2- 58 48 17 27 37 A2- 47 57 67 77 A2- 14 24 34
K1
K2
Red (1)
(Receiver error code)
Charger
contacts
Safety receiver
RSRA
27 to 77 : Control outputs of
radiocontrol function buttons
Emerg. stop 1
24V DC
Orange (1)
Radio
transmitter
active
Green (1)
Equipment
operating
Detect transmitter on
charger
K3
K3
(1) Ind. light
column
Antenna
Start
button
Gate contact open
Output
Input
Passage
request
A2 -
A5 +
IR
K3 K4