Page 6 / 41
Ref doc :
330740F/EN
revision 01
29.09.2015
2
Presentation of RADIOSAFE emergency stop system
2.1 Unpacking the product
The RADIOSAFE product comprises:
One receiver
RSRA
(1)
One transmitter
URE
(2)
One 24VDC-5VDC voltage adapter
UCC4
(3)
One charger support
SCI-B
(4)
Two sheets of labels
UWE202
and
UWE207
(5)
One key identification sheet (6)
One CD (or USB memory key) including the installation and operating instructions manual (7)
One BNC elbow
VUB060
(8)
One antenna extension
VUB170
(9)
One ¼ quarter wave antenna
VUB084
(10)
2.2 Configuration on delivery
Product
• The product is supplied factory-set for radio channel
01, i.e. 433.100 MHz.
Transmitter
•
The transmitter “activity monitoring” function (transmitter automatically stops if not used for an extended period of time)
is factory-set for 15 min.
To modify the duration or change the counting unit to « seconds », refer to the “Transmitter activity monitoring function”
section.
• Electronic key number :
- A unique number is engraved on the key.
IMPORTANT :
When unpacking the products, be sure to stick the electronic key identification label on the key sheet
supplied with the product.
• Locking the transmitter :
- The transmitter is supplied « unlocked » ; the « activity monitoring » and « frequency » configurations corresponding to
the electronic key can be directly modified by a qualified operator.
Receiver
• The receiver has 10 different application programs. It is supplied factory-set for program « 0 » selectable by 2 selectors
"B". For information on the different programs, refer to the section entitled “Choice of receiver (RSRA) program”.
• The receiver has a time delay function. It is supplied with a time delay of 10 seconds for transmitter take-over according
to the position "0" of 2 selectors A
. Refer to the section covering “adjustment of time delay” if this duration is not sufficient.
1
2
3
4
5
6
7
8
9
10