Page 31 / 41
Ref doc :
330740F/EN
revision 01
29.09.2015
8.3.3 Procedure for « locking
– unlocking » access to transmitter programming
1- Switch off the receiver.
2-
Insert the electronic key in the transmitter.
3-
- Press and hold buttons B1, B2 and " On ",
- Unlock the emergency stop palmswitch (fig.1),
- Wait until the orange indicator goes off before releasing buttons B1, B2 and "On".
Led indications :
- transmitter
locked
: orange indicator light on, green indicator light off.
- transmitter
unlocked
: orange and green indicator lights on.
4-
Select the locked or unlocked state by pressing button B2 ; the selected mode is indicated on the indicator
lights (Fig. 2&3).
5-
Validate the selected mode by pressing the
“On” button (Fig.4).
6-
The transmitter (URE) saves the new mode in the electronic key and switches off the indicator lights.
7-
Exit the « lock-unlock » configuration mode by pressing the emergency stop palmswitch (Fig.6).
Note:
If an operator attempts to program the frequency or the duration for the « activity monitoring » time delay
with the transmitter in the locked state, the transmitter will indicate an error by its indicator lights which will flash 4
times.