Ref doc :
330740F/EN
revision 01
29.09.2015
Switch B = 4:
Protection circuits connected to S12-S14 and S22-S24 always active, manual startup by «ON» button
connected to S42
Transmitter acknowledged if one of charger contacts connected to S32 and S34 opens.
Manual startup by transmitter «ON» button possible for all functions.
tmax.: maximum time for transmitter enable after it is picked up off charger.
6.2.2 Control of machine with area access control.
Programs 8 and 9 of the safety receiver are used to manage access to a machine area. The difference between
these two programs is in the reset mode following a wireless emergency stop.
On the other hand, one of the two wired emergency stop inputs is used to manage dangerous area access.
See appendix “A” example application
6.2.2.1 Recommended wiring diagram
All the inputs must be wired
, including the charger contacts, the « ON button» and the emergency stop input. If
emergency stop inputs « S11-S12 and S13-S14 » are not used, they must be bridged two by two.