Section 19 Adjusting and Setting up Equipment (for Services)
19-26
The setting target can be checked with [Source Device] display, [Terminal] display and [Sensor]
display.
Perform the settings shown in the following table and then click on the [Set] button.
Setting Item
Description of Setting
Setting Value
Baud Rate
Select the baud rate of the serial port on the
combo box.
In the [Detail] dialog of any of CH8 to CH10,
the [Baud Rate] addition ratio combo box is
displayed on the right side of the [Baud Rate]
combo box.
Selectable baud rates vary
depending on the serial port
(refer to "Selectable baud
rates").
[Baud Rate] addition ratio
combo box
Displayed in the [Detail] dialog of CH8 to
CH10. By using this combo box, the addition
ratio (%) for adjusting the baud rate can be
changed. The baud rate is determined by
adding the additional ratio to the value that is
set in the [Baud Rate] combo box.
Example) 4800 × (1 + 1.5 / 100) = 4872
Additional ratio
0.0% to 3.0% (can be set in
the unit of 0.5%)
Data Length
Select the data length of the corresponding
serial port from the combo box.
5/6/7/8
Parity
Select the parity of the corresponding serial
port from the combo box.
None/Odd/Even
Stop Bits (Stop Bit Length)
Select the stop bit length of the corresponding
serial port from the combo box.
1/2
Buffer Size
Enter the buffer size of the corresponding
serial port from the list.
0 to 10240 byte
Time Out
Enter the time-out duration of the
corresponding serial port from the list.
0 to 999s
Checksum
Select the check box and enable the
checksum of the sentence of the
corresponding serial port.
To enable: Select.
To disable: Clear.
Subsystem
Set the equipment to be connected for Alert
Handling.
Displayed only when the sensor is "Alert (from
Subsystem) " or "Alert (to CAM) ".
The selection is also allowed for the
subsystem that has already been used in the
channel of some other serial port.
"Alert (from Subsystem) ":
Equipment that is set as
-/installed (Task Station and
sensor)
"Alert (to CAM) ":
Equipment that is set as
-/installed (Task Station)
Primary/Secondary Select
Primary or Secondary for IAS
(MODBUS) input.
Displayed only when the sensor is "IAS
(MODBUS) ".
Primary: Primary system
Secondary: Secondary
system
Содержание JMR-7230-S3
Страница 2: ......
Страница 62: ...Section 19 Adjusting and Setting up Equipment for Services 19 50...
Страница 228: ...Section 22 Failures and After Sale Services 22 50...
Страница 286: ...Appendix A Radar Antenna Block Diagrams A 8 A 8 NKE 2632 2632 H NKE 2632 2632 H Interconnection...
Страница 416: ...Appendix D Menu List and Materials D 34 D 1 16 Code Input Password ECDIS RADAR CONNING...
Страница 488: ...Appendix D Menu List and Materials D 106 Object name Icon button display example Remarks Weed Kelp Wreck...
Страница 536: ...Appendix D Menu List and Materials D 154 No Drawn object name Drawn object display example 8 Plotted Position...
Страница 575: ......