MC 11000
5 mm
(A)
Solenoid
Adjusting Thread Cutter Solenoid
The space between the plunger and the upper surface of the yoke should be 5 mm when the
plunger is operated.
1. Remove the belt cover and base.
2. Loosen the 2 screws (A) and move the set plate
(1) up or down to make the space between the
snap ring (2) of the plunger and the upper sur-
face (3) of the yoke 5 mm.
3. Tighten the screws (A).
4. Attach the base and belt cover.
(1)
(2)
(3)
36
5 mm
(Gauge 860G001)
www.promelectroavtomat.ru