Safety Recommendations
FireStorm ONE Installation Guide
26
BreakingPoint Systems Inc. ©2005-2016
Note:
If one or more fans fail to operate at full speed, the system will shut down. If this occurs,
please contact BreakingPoint Support for further assistance.
Environmental Requirements
The FireStorm ONE must operate under the following environmental requirements:
• Operating environment: 15°C to 40°C (59°F to 104°F)
• Non-operating environment: -20°C to 70°C (-4°F to 158°F)
• Relative Humidity: 5 to 95%, non-condensing
• Altitude: No degradation up to 13,000 feet above sea level
Power Requirements
The FireStorm ONE may be operated on 110VAC (nominal) or 220VAC (nominal) input power.
For North American shipments, power cords are provided with the system for both 110VAC and
220VAC connections. The 220VAC power cord includes a NEMA L6-20P plug and an adapter for
NEMA L6-20P to NEMA 6-20P. International shipments include country-specific power cords.
System Grounding Requirements
Electrostatic Discharge (ESD) can occur if electronic components are improperly handled. ESD
can cause intermittent or complete system failure.
To prevent ESD from occurring, you should eliminate static generators (e.g., plastic) and static
conductors (e.g., metal) from all areas that house electronic equipment or highly charged materials.
Note:
Use proper ESD protection whenever handling any parts of the FireStorm ONE.
Fiber-Optic Connection Requirements
The SFP+ optical transceivers and fiber-optic connections are classified as Class 1 lasers. This
means that exposure to the laser will not cause eye injury and are generally considered safe;
however, we recommend that you do not look directly into the connectors.
The SFP+ optical transceivers from the Accessories Kit come with protective dust covers. You
should install the protective dust covers over the transceivers to protect the optical data ports
whenever they are not in use. If you remove the dust covers later on, be sure to properly store them
so that you can easily find them again.
Note:
Do not remove the SFP optical transceivers from the data ports. When these ports are not in
use, keep the protective dust covers in them.
Safety Recommendations
This section covers the safety recommendations that you must read before installing or operating
the FireStorm ONE. Keep in mind that any electronic equipment – like the appliance – can create a
dangerous environment for employees and surrounding equipment if it is installed improperly.
Содержание BreakingPoint Storm
Страница 1: ...FireStorm ONE Installation Guide Release 8 0 1 Mar 2016...
Страница 9: ...Documentation Feedback FireStorm ONE Installation Guide iv BreakingPoint Systems Inc 2005 2016...
Страница 15: ...Control Center Overview FireStorm ONE Installation Guide 6 BreakingPoint Systems Inc 2005 2016...
Страница 46: ...Initial Configuration FireStorm ONE Installation Guide 38 BreakingPoint Systems Inc 2005 2016...
Страница 48: ...Accessing the Control Center FireStorm ONE Installation Guide 40 BreakingPoint Systems Inc 2005 2016...
Страница 54: ...Update Questions FireStorm ONE Installation Guide 46 BreakingPoint Systems Inc 2005 2015...