RELAY OUTPUTS & VIRTUAL (CONTROL) OUTPUTS
Percent Timer (R1-R6, C1-C6)
Off
HOA Setting
Sample Period
Feed Percentage
Output Time Limit
Additional settings for Percent Timer Mode:
Reset Output Timeout
Interlock Channels
Activate with Channels
Minimum Relay Cycle
Hand Time Limit
Reset Time Total
Name
Mode
Alarm (R1-R6, C1-C6)
Off
HOA Setting
Alarm Mode
On Delay Time
Off Delay Time
Additional settings for Alarm Mode:
Select Alarms
Output
Interlock Channels
Activate with Channels
Minimum Relay Cycle
Hand Time Limit
Reset Time Total
Name
Mode
Time Prop (R1-R6, C1-C6)
Off
HOA Setting
Set Point
Proportional Band
Sample Period
Additional settings for Time Prop Mode:
Daily Max Time
Output Time Limit
Reset Output Timeout
Interlock Channels
Activate with Channels
Minimum Relay Cycle
Hand Time Limit
Reset Time Total
Input
Direction
Name
Mode
Manual (R1-R6, C1-C6)
Off
HOA Setting
On Delay Time
Off Delay Time
Output Time Limit
Additional settings for Manual Mode:
Reset Output Timeout
Interlock Channels
Minimum Relay Cycle
Hand Time Limit
Reset Time Total
Name
Mode
Pulse Prop (R1-R6, C1-C6)
Off
HOA Setting
Set Point
Proportional Band
Minimum/Maximum Output
Additional settings for Pulse Prop Mode:
Maximum Rate
Interlock Channels
Activate with Channels
Minimum Relay Cycle
Hand Time Limit
Reset Time Total
Input
Direction
Name
Mod
Dual Setpoint (R1-R6, C1-C6)
Off
HOA Setting
Set Point
Set Point 2
Deadband
Additional settings for Dual Setpoint Mode:
Duty Cycle Period
Duty Cycle
On Delay Time
Off Delay Time
Output Time Limit
Reset Output Timeout
Interlock Channels
Activate with Channels
Minimum Relay Cycle
Hand Time Limit
Reset Time Total
Input
Direction
Name
Mode
Probe Wash (R1-R6, C1-C6)
Off
HOA Setting
Event 1 (through 10)
Repetition
Hourly
Additional settings for Probe Wash Mode:
Week
Day
Events Per Day
Start Time
Duration
Input
Input 2
Sensor Mode
Hold Time
Interlock Channels
Activate with
Channels
Minimum Relay
Cycle
Hand Time Limit
Reset Time Total
Name
Mode
Only if Pulse Relay Type
Additional settings for Lag Control Mode:
Additional settings for Flow Prop Control Mode:
Lag Control (R1-R6)
Off
HOA Setting
Lead
Wear Leveling*
Wear Cycle Time*
Activation Mode*
Set Point
Set Point 2
Deadband
Delay Time*
Output Time Limit
Reset Output Timeout
Interlock Channels
Activate with Channels
Min Relay Cycle
Hand Time Limit
Reset Time Total
Name
Mode
* See section 5.3.18
Flow Prop (R1-R6, C1-C6)
Off
HOA Setting
Target
Pump Capacity
Pump Setting
Specific Gravity
Maximum Rate
Output Time Limit
Reset Output Timeout
Interlock Channels
Activate with Channels
Hand Time Limit
Reset Time Total
Flow Input
Cycles Input
Low Cycles Limit
Name
Mode
Not available for virtual outputs
Only if Pulse Relay Type