43
Ope
ra
tio
n
Operation programming
Operation programming
The pump operation is programmed and controlled by a control unit.
The pump is controlled in different ways at each operation mode.
Default setting and setting range
Parameters
Default setting
Setting range
Step
Stroke rate*
1
360
(VH/PH-V: 300spm)
1-360
(VH/PH-V:1-300spm)
1*
2
Multiply/Divide se-
lection
/NNN
/NNN, XNNN
-
Divider
1
1-999
1*
2
Multiplier
1
1-999
1*
2
Display selection
E-EX
E-EX/E-SP
-
Anti-chattering pro-
gramming*
3
T-5
T-5/T-10/T-50
-
STOP function*
4
M-OF
M-ON/M-OF
-
*1 The upper limit spm in EXT mode
*2 spm increases/decreases as pushing the UP/DOWN keys. Pressing either key for
more than three seconds, spm changes quickly.
*3 The controller becomes more resistant to chattering as read time is set longer but
then becomes less capable of reading the short pulse signal. "T-5", "T-10" and "T50"
are the approximate time (msec) to read the external pulse signal. An ON time pe-
riod of the pulse signal shall be longer than the read time.
*4 Note that the pump starts to run as returning to the wait state in the manual mode as
long as the pump is receiving the STOP signal and "M-ON" is selected.
Содержание EHN-R
Страница 91: ...91...