84 Speci
fi
cation/Outer dimension
PH-H (High compression type)
Model code
Flow
rate
m
ℓ
/min
Max.
discharge
pressure
MPa
Stroke
length
mm
(%)
Stroke
rate
spm
Tube con-
nection bore
mm
Power
con-
sump-
tion
W
Current
value
A
Weight
kg
EHN-B11PH-H
30
1.5
0.5-1.0
(50-100)
1-360
IN: ø4×ø9
OUT: ø4×ø6
20
0.8
1.8
EHN-C16PH-H
60
1.5
0.5-1.25
(40-100)
24
1.2
2.9
VH/PH-V type (Viscosity type)
Model code
Flow
rate
m
ℓ
/min
Max.
discharge
pressure
MPa
Stroke
length
mm
(%)
Stroke
rate
spm
Tube con-
nection bore
mm
Power
con-
sump-
tion
W
Current
value
A
Weight
kg
EHN-C31VH/
PH-V
220
0.35
0.5-1.25
(40-100)
1-300
ø8×ø13
24
1.2
2.9
EHN-C36VH/
PH-V
350
0.2
* These speci
fi
cations are based on pumping ambient clean water at rated voltage.
* Flow rate is collected at the maximum discharge pressure, 100% stroke length and
360spm (300spm for the VH/PH-V). The
fl
ow rate increases as a discharge pressure
decreases.
* Allowable room temperature: 0-40°C
* Allowable liquid temperature: 0-40°C (0-60°C for the PC•PH•PP•FC)
*The PP type is not available with B21 and C16.
* Allowable voltage deviation: ±10% of the rated voltage
* For the VH/PH-V types, their
fl
ow rate is collected with clean water and is not war-
ranted for viscous liquid. The
fl
ow rate may increase or decrease depending on liquid
characteristics.
Содержание EHN-R
Страница 91: ...91...