NOTE
• Do not install the EXT/STOP signal wires in parallel with a power cable or combine
them in a concentric cable (ex. 5 wires cable). Otherwise noise is generated through
the EXT/STOP signal wires due to induction effect and it results in malfunction or
failure.
• When using the SSR (Solid State Relay) for the EXT/STOP signal input, see the rec-
ommended products below. Any SSR other than the recommended ones can cause
malfunction. See manufacturer's information such as catalogues for detail.
–OMRON G3FD-102S or G3FD-102SN
–OMRON G3TA-IDZR02S or G3TA-IDZR02SM
• When using a contact type relay for the EXT/STOP signal input, the minimum applica-
tion load should be 5mA or below.
*Use either a no-voltage contact or an open collector for the external signal.
* Set pulse duration in 10-100ms and the number of pulses at or below 360 pulses per
minute (For the VH/PH-V type set at or below 300 pulses per minute).
Remove the control unit.
a.
Remove the rubber cap,
fi
screw and gasket from the top.
b. Loosen the two tapping screws (A)
located above the stroke length
adjusting knob and detach the
control unit.
Fixing screw
Rubber cap
Gasket
Tapping screws A