39
Ope
ra
tio
n
Before operation
Flow rate, stroke rate and stroke length
Precautions of
fl
ow rate adjustment
•
When back pressure is high
Set stroke length to 100% and adjust the
fl
ow by changing a stroke rate.
•
When the
fl
ow rate per shot greatly in
fl
uences the reaction in neutrali-
zation or titration application
Shorten the stroke length to reduce the
fl
ow rate per shot. And then adjust the
fl
ow by changing a stroke rate.
•
When pumping gaseous liquid such as sodium hypochlorite (NaClO)
and hydrazine solution (N
2
H
2
O
2
)
Set stroke length to 100% and adjust the
fl
ow by changing stroke rate.
Air lock may occur when stroke length is set short.
■
Stroke rate adjustment
Stroke rate can be set by keypad operation.
The stroke rate can be programmed from 1 to 360spm (1 to 300spm for VH/
PH-V).
The relation between a
fl
ow rate* and stroke rate is shown as below.
B type
C type
* The
fl
ow rate described on the
nameplate is at 100%.
Fixed stroke rate
100
%
75
50
25
0
25
50
75
100
%
Di
sc
h
a
rg
e c
a
p
a
ci
ty
Stroke length adjustment
360spm
(Stroke rate is fixed at 100%.)
270spm
(Stroke rate is fixed at 75%.)
180spm
(Stroke rate is fixed at 50%.)
Fixed stroke rate
100
%
75
50
25
0
25
50
75
100
%
Di
sc
h
a
rg
e c
a
p
a
ci
ty
Stroke length adjustment
360spm (VH/PH-V:300spm)
(Stroke rate is fixed at 100%.)
270spm (VH/PH-V:225spm)
(Stroke rate is fixed at 75%.)
180spm (VH/PH-V:150spm)
(Stroke rate is fixed at 50%.)
Fixed stroke length
100
%
75
50
25
0
180
360
spm
D
isc
harge
c
apac
it
y
Stroke rate adjustment
Содержание EHN-R
Страница 91: ...91...