- 50 -
■
Replacement of diaphragm
<Disassembly>
z
Set the stroke length adjusting dial at 100%.
x
Remove the pump head from the pump unit by loosening the four hexagon socket bolts with a hexagon bar wrench.
c
Hold the periphery of the diaphragm and rotate it
counterclockwise to detach it from the plunger
pin. (The diaphragm is screwed onto the plunger
pin.)
•
In some cases, a certain number of diaphragm
spacers are inserted behind the diaphragm and
the retainer for the purpose of positioning. Be
careful not to lose them when replacing the
diaphragm.
<Reassembly>
For reassembly, follow the steps of disassembly in
reverse, paying attention to the following.
z
Firtst, make sure that the stroke length of the
pump is set at 100%.
•
Start up the pump for setting the stroke length.
Then, stop the pump and turm the power off.
x
Insert the retainer and diaphragm spacer(s) onto
the threaded part of a new diaphragm and screw
the plunger pin into it.
•
Fit the concave side of the retainer onto the
threaded part of the diaphragm.
c
Attach the pump head(1) to the pump body by
tightening the hexagon socket bolt.
(Clampimg torque: 2.16N·m {22kgf·cm})
Pump head
Plunger Pin
Diaphragm spacer
Retainer
Diaphragm
Содержание EH-B10
Страница 16: ... 14 INSTALLATION 1 Before Use 15 2 Notes on Operation 15 3 Installation Piping and Wiring 18 ...
Страница 28: ... 26 PUMP OPERATION 1 Operation 27 2 Methodsn of Pump Operation 33 ...
Страница 61: ... 59 MEMO ...
Страница 62: ... 60 MEMO ...
Страница 63: ... 61 MEMO ...