- 28 -
c
Press the
key to select "MAN." Then, "WAIT"
will be displayed.
v
Press the
key once.
•
The display panel on the control unit displays "360"
and the pump starts operating. (Stroke rate initial set
value: 360 spm)
*
Every time you press the
key, the pump starts or
stops operating.
START
S T O P
START
S T O P
F U N C
Caution
•
Do not run the pump with the discharge-side valve closed.
Operating the pump with the discharge-side valve fully closed may cause a liquid leakage or a rupture
in the piping. Never operate the pump with the discharge-side valve completely closed.
•
Do not operate the pump dry.
Operating a pump filled with liquid after dry operation may result in liquid leakage. Make sure to
operate the pump with sufficient liquid inside.
* If the pump is operated dry for a long time (30 min. or longer), the pump may be heated excessively,
which will result in liquid leakage due to the deformation of the pump unit (pump head, valve case, etc.)
and/or loosened pump head assembly.
•
Loosened pump head
Loosened installation bolts on the pump head may result in liquid leakage.
* Prior to the initial pump run, fasten the 4 hex socket bolts. (During pump storage or transportation, the
hex socket bolts may be loosened.)
* Fastening torque: 2.16 N·m {22 kgf·cm}
Tighten all the hex socket bolts fully by applying an equal torque in a diagonal order among the bolts.
START
S T O P
F U N C
START
S T O P
F U N C
MAN
ZERO SPAN
AUTO
°
C
ALM
SET
PB
spm
pH
Hi
Lo
START
S T O P
F U N C
START
S T O P
F U N C
MAN
ZERO SPAN
AUTO
°
C
ALM
SET
PB
spm
pH
Hi
Lo
*
Содержание EH-B10
Страница 16: ... 14 INSTALLATION 1 Before Use 15 2 Notes on Operation 15 3 Installation Piping and Wiring 18 ...
Страница 28: ... 26 PUMP OPERATION 1 Operation 27 2 Methodsn of Pump Operation 33 ...
Страница 61: ... 59 MEMO ...
Страница 62: ... 60 MEMO ...
Страница 63: ... 61 MEMO ...