- 29 -
■
Procedure for air bleeding in EH-B10, 15, 20, C15, and 20 types
z
Open the air vent valve to put the pump in operation.
The air vent valve can be opened when the air vent
adjusting screw is turned counterclockwise (about haif
a rotation).
x
In this state, leave the pump running for about 10
minutes to let the air out.
•
Bleed air from the tube on the suction side and the
pump head, and fill them with water.
c
Close the air discharge port by turning the air vent
adjusting screw.
v
Finally, make sure that no liquid leaks from any part.
■
Procedure for air bleeding in EH-B30, C30, and C35 types
z
Return the tube connected to the fitting nut on the discharge side to the liquid tank or a drain plate.
•
If the check valve is attached to the discharge side valve, it should be detached before the above step
z
.
Caution
Some types of liquid will damage skin and machine parts. If your hand or any of the pump parts is exposed to such
liquid, wipe it away immediately.
x
Run the pump for about 10 minutes to bleed air.
c
After letting the air out of the pump head and fitting the pump head with water, reconnect the discharge side tube to
the regular piping.
v
Finally, make sure that there is no leakage in any part.