- 20 -
w
If the pressure on the suction side is higher than that
on the discharge side (Fig. B).
e
The liquid surface on the discharge side liquid is
higher than that of the suction side, but the
difference between the two levels is 5 m or less (Fig.
C).
r
The load pressure (pipie resistance, discharge pump
head, etc.) applied to the pump is 0.13 MPa
{1.3 kgf/cm
2
} or less.
<Note on installation of check valve>
•
Install the check valve at the edge of the discharge side
connecting tube. It must be least 1 m away from the
pump .
•
The connection port of the CA type check valve can be
mated with not only the tube but R1/2 and R3/8 threads.
Cut off the unnecessaly section with a pipe cutter.
(For applicable pump types, see 'Accessories' on page
52.)
•
Besides the CA type, the CB double-ended type
(optional item) for connection to braided tube is
available.
•
A back pressure valve (optional item) can be used in
place of the check valve. For details, can Iwaki.
Fig. B
Fig. C
R1/2
R3/8
Diameter
φ
9
CA type check valve
BV type back pressure valve
BVC type back pressure valve
CB type check valve
5m